Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 06/24/2008 |
ELECTRIC - INTERMEDIATE |
|
Approved |
|
| 04/17/2000 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000* |
| 04/12/2000 |
ELECTRIC - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - DENIED - 1. NEED CITY OF TUCSON APPROVED PLAN. 2. GROUND ALL METAL ELECTRIC BOXES. 3. LAUNDRY MUST HAVE 2 WASTE AND TRAP. 4. DRYER OUTLET IS NOT COMPLETE. 5. GAS LINE HAS BEEN REPLACED. MUST BE ON PLAN AND MUST HAVE MINIMUM OF 10 PSI GAS TEST. 6. GAS LINE REQUIRES ELECTRIC BOND. 7. WATER HEATER VENT MUST EXTEND 1 FOOT ABOVE ROOF. 8. REMODELED ATTIC CEILING FOR BEDROOM HAS LESS THAN 7 FOOT HEAD ROOM. APPROXIMATELY 6-8. 9. STAIRS REQUIRE GUARD RAILS. 10. METAL BASE BOARD BOXES MUST BE SECURED TO WALL AND REQUIRE GROUNDING. OPEN ALL BOXES. 11. BASEMENT WASTE AT NORTHWEST CORNER IS NOT PER CODE. |
| 04/12/2000 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999* |