Permit: T00CM00281

Parcel: 141110700

Inspection Status: Correction Required

Inspection History: FRAMING

Permit Number - T00CM00281

Inspection Description - FRAMING

Inspection Status - Correction Required

Date Description Inspector Results Comments
02/23/2000 FRAMING Correction Required ADDTL COMMS - APPROVED - PICK-UP OKAY.
02/22/2000 FRAMING Correction Required ADDTL COMMS - DENIED 1. PEX LINES MUST BE 12 FROM CAN LIGHTS. 2. HEADERS IN BEARING WALLS MUST BEAR ON TRIMMERS. 3. BEARING AND SHEARWALL PLATES REQUIRE ABS WITHIN 12 OF ENDS. 4. VENT FAN IN MASTER WC MUST BE LOWERED TO CEILING LEVEL. 5. FHA STRAPS REQUIRE 3 NAILS PER END. 6. PLUMBING BOX AT KITCHEN SINK MUST BE MOVED TO FACE OF FRAMING. 7. REPLACE FIRE BLOCKING AT MASTER WATER CLOSET.
02/22/2000 FRAMING Denied IVRS - Inspection 0999*
02/18/2000 FRAMING Not ready for Inspection IVRS - Inspection 0000*