Inspection History Details
Inspection Status: Correction Required
Inspection History: FRAMING
Permit Number - T00CM00281
Inspection Description - FRAMING
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/23/2000 | FRAMING | Correction Required | ADDTL COMMS - APPROVED - PICK-UP OKAY. | |
| 02/22/2000 | FRAMING | Correction Required | ADDTL COMMS - DENIED 1. PEX LINES MUST BE 12 FROM CAN LIGHTS. 2. HEADERS IN BEARING WALLS MUST BEAR ON TRIMMERS. 3. BEARING AND SHEARWALL PLATES REQUIRE ABS WITHIN 12 OF ENDS. 4. VENT FAN IN MASTER WC MUST BE LOWERED TO CEILING LEVEL. 5. FHA STRAPS REQUIRE 3 NAILS PER END. 6. PLUMBING BOX AT KITCHEN SINK MUST BE MOVED TO FACE OF FRAMING. 7. REPLACE FIRE BLOCKING AT MASTER WATER CLOSET. | |
| 02/22/2000 | FRAMING | Denied | IVRS - Inspection 0999* | |
| 02/18/2000 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |