Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/03/2009 |
ROOF NAILING |
|
Approved |
|
| 04/19/2000 |
ROOF NAILING |
|
Correction Required |
ADDTL COMMS - DENIED - 1. PLAN CALLS FOR 2X8 RAFTERS AT 16 O.C. INSTALLED AT 24 O.C. 2. PLAN CALLS FOR 2-EACH 5040 WINDOWS AND A 10 FOOT SLIDING DOOR. INSTALLED ARE 2-EACH 4040 WINDOWS AND A 6068 SLIDING GLASS DOOR. REVISE PLAN TO AS BUILT. 3. GROUND ALL METAL ELECTRIC BOXES. 4. WIRE SPLICES MUST OCCUR IN APPROVED ELECTRIC BOXES. 5. FAN BOXES CANNOT BE SECURED WITH DRYWALL SCREWS. MINIMUM 2-#12 SCREWS. 6. NAIL PROTECT WIRES WITHIN 1-1/4 OF STUD SURFACE. |
| 04/19/2000 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999* |