Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T00CM00250

Parcel: 130080300


Addresses:

3734 E 27TH ST

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
03/03/2009 ROOF NAILING Approved
04/19/2000 ROOF NAILING Correction Required ADDTL COMMS - DENIED - 1. PLAN CALLS FOR 2X8 RAFTERS AT 16 O.C. INSTALLED AT 24 O.C. 2. PLAN CALLS FOR 2-EACH 5040 WINDOWS AND A 10 FOOT SLIDING DOOR. INSTALLED ARE 2-EACH 4040 WINDOWS AND A 6068 SLIDING GLASS DOOR. REVISE PLAN TO AS BUILT. 3. GROUND ALL METAL ELECTRIC BOXES. 4. WIRE SPLICES MUST OCCUR IN APPROVED ELECTRIC BOXES. 5. FAN BOXES CANNOT BE SECURED WITH DRYWALL SCREWS. MINIMUM 2-#12 SCREWS. 6. NAIL PROTECT WIRES WITHIN 1-1/4 OF STUD SURFACE.
04/19/2000 ROOF NAILING Denied IVRS - Inspection 0999*