Permit: T00CM00190

Inspection Status: Correction Required

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
05/19/2000 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. WASTE AND VENT SYSTEM OK 2. OVERHEAD WATER DISTRIBUTION OK 3. WATER TEST ON WASTE OK 4. ALL CORRECTIONS HAVE BEEN MADE 5. OK FOR DRYWALL
05/17/2000 PLUMBING - INTERMEDIATE Correction Required ADDTL COMMS - 1. CLOSET RINGS NOT SET AT THIS TIME 2. C.O. FOR A. WASHERS MUST BE ON VERTICAL 3. KIT SINK HORIZONTAL VENT MUST BE 6 ABOVE FLOOD RIM LEVEL. 4. PROVIDE WATER TEST ON WASTE AND VENT SYSTEM
05/17/2000 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0000*