Permit: T00CM00173

Parcel: 110082450

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
03/08/2000 BUILDING - FINAL Approved
02/25/2000 BUILDING - FINAL Denied IVRS - Inspection 0999*
02/24/2000 BUILDING - FINAL Correction Required ADDTL COMMS - DENIED 1. NEED SMOKE DETECTORS THROUGHOUT THE HOUSE. 2. NEED GFI AT KITCHEN TO THE RIGHT OF STOVE. 3. HAVE OPEN NEUTRAL IN LAUNDRY ROOM OUTLET. 4. PAINT ALL VENT PIPE ON ROOF. 5. GROUND METAL BOX ABOVE KITCHEN.
02/24/2000 BUILDING - FINAL Cancelled IVRS - Ri canceled
01/26/2000 BUILDING - FINAL Correction Required ADDTL COMMS - THIS HOUSE APPEARS STRUCTURALLY UNSOUND. ACCORDING TO ORIGINAL PLANS THERE WAS A CONTINUOUS 6X12 BEAM SUPPORTED BY 6X6 POSTS AT 6 O.C. THE POSTS HAVE BEEN REMOVED AND THE BEAM PRESENTLY SPANS 18-11 WITH AN INTERSECTING BEAM APPROXIMATELY 5 FEET FROM THE SOUTH BEARING POINT. THAT INTERSECTING BEAM WHICH SPANS APPROXIMATELY 19-2 HAS AN ADDITIONAL 6X12 BEAM APPROXIMATELY 16 LONG, INTERSECTS THE OTHER BEAM AT MID POINT. SUGGEST AN ENGINEERING EVALUATION OF THE 18-11 SPANNING BEAM 6X12 BEAM, DUE TO THE REMOVAL OF THE SUPPORTING POSTS.
01/26/2000 BUILDING - FINAL Denied IVRS - Inspection 0999*
01/25/2000 BUILDING - FINAL Correction Required ADDTL COMMS - EXPOSE KITCHEN DINING ROOM BEAMS 12 EACH FROM A POINT 6 2 FROM EACH WALL TO EXPOSE BEARING BEAM.
01/25/2000 BUILDING - FINAL Denied IVRS - Inspection 0999*
01/24/2000 BUILDING - FINAL Correction Required ADDTL COMMS - 1. PROVIDE ORIGINAL PLANS OF HOUSE OR EXPOSE GLUE LAM BEAM AT/OR EXPOSE BEAMS AND BEAM ABOVE KITCHEN AND DINING ROOM. 2. TWO 60 PATIO DOORS REQUIRE STOOPS ENTIRE WIDTH OF OPENING. ALSO, GARAGE PERSONNEL DOOR.
01/24/2000 BUILDING - FINAL Denied IVRS - Inspection 0999*