Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T00CM00030
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/27/2000 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - APPROVED - BACK COLUMN WEST NEEDS POST TO BEAM CONNECTION. EXTERIOR SOLE PLATE, ADD NAILS PER SCHEDULE. TWO 2- 16ds AT 12 O.C. 3 HOLD-DOWNS ARE MISSING INSIDE. CHECK AT FRAMING. | |
| 03/23/2000 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000* | |
| 03/21/2000 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - DENIED - 1. INSTALL PA RIGHT SIDE OF ENTRY DOOR. 2. SW1 WRONG LOCATION AT REAR. 3. MINIMUM 2 BOLTS PER SW SECTION. 4. NEED STUD BEARING UNDER ALL HEADERS. 5. 2 NAILS TOP AND BOTTOM BRACING. | |
| 03/21/2000 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999* |