Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/15/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - APPROVED - REINSPECT. |
| 03/13/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - DENIED - STOPPED INSPECTION - TOO MANY ITEMS. 1. CS 16 X 42 STRPAS ARE MISSING AT 2ND FLOOR SHEAR. 2. SUPPORT HORIZONTAL D.W.V. AT 4 O.C. 3. PLUMBING STRAP IS NOT LISTED FOR SUPPORTING D.W.V. USE PROPER SUPPORT. 4. HORIZONTAL WET VENT IS NOT ALLOWED AT SHOWER. 5. TUB/SHOWER IS NOT PROPERLY VENTED. 6. COPPER PLUMBING IS IN CONTACT WITH CONCRETE. MUST BE WRAPPED. 7. NO TRUSS DRAWINGS ON JOB SITE. 8. B GAS VENT WITHIN 1 OF COMBUSTIBLES AT 2ND FLOOR CLOSET. |
| 03/13/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |