Inspection Status: Correction Required
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 04/13/2000 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. WASTE AND VENT SYSTEM OK 2. RAIN LEADER WATER TEST OK 3. ALL CORRECTIONS HAVE BEEN MADE 4. OK TO DRYWALL |
| 04/05/2000 |
PLUMBING - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. GAS PRESSURE TEST OK 2. MUST TEST RAIN LEADERS 3. WASTE LINE FOR 2ND FL LAVATORY HAS 1/4 BEND ON A HORIZONTAL DRAIN. MUST BE L-SWEEP 4. RE TEST SYSTEM |
| 04/05/2000 |
PLUMBING - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0000* |