Permit: T00CM00017

Parcel: 111022880


Addresses:

3838 N BORG LN

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
09/18/2000 ELECTRIC - INTERMEDIATE Approved
04/05/2000 ELECTRIC - INTERMEDIATE Correction Required ADDTL COMMS - 1. NAIL ROMEX TO WASHER RECEPTACLE 2. NAIL ROMEX TO KITCHEN RECEPTACLE WITHIN 8 IF NO CLAMP ON BOX 3.STRAP ALL WIRING BEFORE ENTERING BACK SIDE OF PANEL (NO HOLDING CLAMP IN PANEL-CONDUCTORS TO BE SUPPORTED) 4. BATH ROOM 2ND FLOOR-EX FAN NOT TIED IN AND LOOSE WIRE IN CEILING 5. 2ND FLOOR HALL CLOSET ROMEX TO RECESSED LT NOT SUPPORTED NOTE-RECHECK ALL ROMEX WIRING SUPPORT-IF CLAMP USED IN BOX STAPLE W/IN 12- NO CLAMP W/IN 8 AND EVERY 4 1/2
04/05/2000 ELECTRIC - INTERMEDIATE Denied DENIED