Inspection Status: Not ready for Inspection
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/26/2001 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000$/1. NO INSPECTION MADE OR APPROVED FOR- A. CONCRETE SLAB AND FTGS. B. ROOF NAILING. 2. DIG INSPECTION HOLES AT POST TO VERIFY FOOTING DEPTH (PER PLAN). 3. USED O.S.B. RIPPING SMALLER THAN 12" WIDTH ONE SPAN IS BROKEN. 4. O.S.B. ROOF DECK NOT NAILED AT LEDGER. 5. POST BASES TIGHTEN ALL NUTS, EACH MUST HAVE A WASHER. 6. POST TO BEAM REQS CONNECTION EACH SIDE. 7. NO ROOF NAILING INSP. ALREADY ROOFED COVERED. |
| 01/19/2001 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/NO ONE HOME. 2. NO PLNAS OR PERMIT POSTED PLEASE RECALL. |