Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: POOL/SPA PLUMBING

Permit Number - T00BU02409

Inspection Description - POOL/SPA PLUMBING

Inspection Status - Approved

Date Description Inspector Results Comments
11/14/2000 POOL/SPA PLUMBING Approved
09/07/2000 POOL/SPA PLUMBING Partial Approval IVRS - Inspection 0000*/1. THE DOUBLE CHECK VALVE INSTALLED IN THE AUTO FILL LINE DOES NOT COMPLY WITH U. P. C. PARAGRAPH 6-3 OR TABLE 6-1 OR INSTALLATION STANDARDS WHEN YOU HAVE A VALVE (AUTO FILL FLOAT) DOWN STREAM. NOTE: POOL HEATER WILL REQUIRE A PRESSURE/TEMPERATURE RELIEF VALVE SINCE THERE IS A VALVE BETWEEN HEATER AND POOL.