Inspection Status: Denied
Inspection History: POOL/SPA FINAL/BARRIER
| Date |
Description |
Inspector |
Results |
Comments |
| 09/05/2000 |
POOL/SPA FINAL/BARRIER |
|
Denied |
IVRS - Inspection 0810*/1. GATES INTO POOL ENCLOSURE MUST BE SELF CLOSING, SELF LATCHING WITHOUT THE AID OF ADDITIONAL MECHNICAL DEVICES SUCH AS PADLOCKS AND PINS YOUR DOUBLE VEHICLE GATE DOES NOT MEET CODE. 2. PROVIDE A PERMIT/PLAN FOR THE 6' HIGH BLOCK WALL AROUND THE POOL ENCLOSURE AND PROPERTY. |
| 08/30/2000 |
POOL/SPA FINAL/BARRIER |
|
Denied |
IVRS - Inspection 0999*/1. GATES INTO POOL ENCLOSURE MUST BE SELF CLOSING SELF LATCHING WITHOUT THE AID OF ADDITIONAL MECHANICAL VEHICLE GATE DOES NOT MEET CODE. 2. METAL FENCE WITHIN 5 FEET OF POOL WATER MUST BE ELECTRICALLY BONDED TO POOL EQUIPMENT. 3. ELECTRIC OUTLET IN POOL ENCLOSURE MUST BE GFCI PROTECTED. 4. PROVIDE PERMIT/PLAN FOR 6' HIGH BLOCK WALL AROUND POOL ENCLOSURE AND PROPERTY. 5. THE INSTALLED DOUBLE CHECK VALVE DOES NOT COMPLY WITH THE UNIFORM PLUMBING CODE TABLE 6-1 AND PARAGRAPH 603.4 FOR BACKFLOW PREVENTION FOR POOL AUTO FILL WITH A VALVE DOWN STREAM. 6. ELECTRIC SWITCH MUST BE PROPERLY GROUNDED. |