Permit: T00BU01982

Parcel: 122163410


Addresses:

3521 E EDISON ST

Inspection Status: Denied

Inspection History: POOL/SPA FINAL/BARRIER

Date Description Inspector Results Comments
09/05/2000 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection 0810*/1. GATES INTO POOL ENCLOSURE MUST BE SELF CLOSING, SELF LATCHING WITHOUT THE AID OF ADDITIONAL MECHNICAL DEVICES SUCH AS PADLOCKS AND PINS YOUR DOUBLE VEHICLE GATE DOES NOT MEET CODE. 2. PROVIDE A PERMIT/PLAN FOR THE 6' HIGH BLOCK WALL AROUND THE POOL ENCLOSURE AND PROPERTY.
08/30/2000 POOL/SPA FINAL/BARRIER Denied IVRS - Inspection 0999*/1. GATES INTO POOL ENCLOSURE MUST BE SELF CLOSING SELF LATCHING WITHOUT THE AID OF ADDITIONAL MECHANICAL VEHICLE GATE DOES NOT MEET CODE. 2. METAL FENCE WITHIN 5 FEET OF POOL WATER MUST BE ELECTRICALLY BONDED TO POOL EQUIPMENT. 3. ELECTRIC OUTLET IN POOL ENCLOSURE MUST BE GFCI PROTECTED. 4. PROVIDE PERMIT/PLAN FOR 6' HIGH BLOCK WALL AROUND POOL ENCLOSURE AND PROPERTY. 5. THE INSTALLED DOUBLE CHECK VALVE DOES NOT COMPLY WITH THE UNIFORM PLUMBING CODE TABLE 6-1 AND PARAGRAPH 603.4 FOR BACKFLOW PREVENTION FOR POOL AUTO FILL WITH A VALVE DOWN STREAM. 6. ELECTRIC SWITCH MUST BE PROPERLY GROUNDED.