Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA ELECTRIC
Permit Number - T00BU01843
Inspection Description - POOL/SPA ELECTRIC
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/14/2001 | POOL/SPA ELECTRIC | Approved | IVRS - Inspection 0000* | |
| 06/06/2001 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection 0999*/ 1) EXCESS OF 4" EXISTS BETWEEN BOTTOM RAIL OF FENCE AND GROUND 2) POOL HEATER EXHAUST CANNOT BE WITHIN 4' OF PROPERTY LINE 3) DIRT MOUNTED UNDER FENCE MUST BE COMPACTED AND PERMANENT | |
| 05/31/2001 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection 0999*/ 1) POOL METAL FENCE WITHIN 5' OF WATER MUST BE BONDED TO POOL EQUIPMENT, NOT TO A GROUND ROD 2) EXCESS OF 4" EXISTS BETWEEN BOTTOM RAIL OF FENCE AND GROUND 3) POOL HEATER EXHAUST CANNOT BE WITHIN 4' OF PROPERTY LINE | |
| 04/23/2001 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection 0999*/1) PROVIDE BOND AT BARRIER 2) DOES NOT LATCH PROPERLY |