Date Description Inspector Results Comments
03/04/2009 BUILDING - FINAL Denied FOUND 3 PATIOS CONSTUCTED AT 3 DIFFERENT TIMES.

1ST PATIO AT BACK DOOR APPEARS TO HAVE BEEN CONSTRUCTED WITH THE HOME AND IS CODE COMPLIANT.

2ND ON EAST SIDE (16'x32') APPEARS TO HAVE UNDERSIZED BEAMS, AND MAY HAVE IMPROPERLY EXTENDED MASONRY COLUMNS. COULD NOT VERIFY COLUMN NOR FOOTING CONSTRUCTION. WOOD FRAMING IS ALREADY SEVERLY DEFLECTED FROM THE DEAD LOADS.

3RD COVER IS TIED TO THE FIRST TWO COVERS WITH HANGERS. SIZING OF ROOF FRAMING IS QUESTIONABLE AND FOOTINGS FOR 4x4 POSTS COULD NOT BE VERIFIED.
06/27/2008 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
HAVE APPROVED PLANS ON SITE,
FOR INSPECTION