Permit: T00BU01382

Parcel: 130111050

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/31/2000 BUILDING - FINAL Approved IVRS - Inspection 0000*
10/10/2000 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*
COMPLETE RAFTERS AT STG. AREA (OKAY TO DBL)
COMPLETE HARDWARE AT RIDGE
COMPLETE NAILING
10/02/2000 BUILDING - FINAL Partial Approval RAFTERS TO BE 2X6 AT 16" C.C. PORCH AND AT STORAGE
2. FILL ALL NAIL HOLES IN HARDWARE AT PORCH AND STORAGE
PROVIDE CONNECTION BETWEEN DBL 2X12 AND EXISTING PLATE AND DRY PACK THIS END OF THE BEAM TO WALL
PROVIDE H2.5'4 AT RIDGE OF STORAGE (RAFTER/ BEAM AND PLATE)