Permit: T00BU00856

Parcel: 114516950


Addresses:

8705 E HONEYBEAR PL

Inspection Status: Approved

Inspection History: POOL/SPA PRE-GUNITE

Date Description Inspector Results Comments
05/16/2000 POOL/SPA PRE-GUNITE Approved
04/06/2000 POOL/SPA PRE-GUNITE Correction Required ADDTL COMMS - PARTIAL - INCOMPLETE. BONDING IS OKAY TO REBAR EXCEPT IRON FENCE CAGE IF APPLICABLE. NEED APPROVED TESTABLE BACKFLOW DEVICE FOR WATER SUPPLY. CHECK AT FINAL.
04/06/2000 POOL/SPA PRE-GUNITE Partial Approval IVRS - Inspection 0000*
04/04/2000 POOL/SPA PRE-GUNITE Correction Required ADDTL COMMS - DENIED - 1. PLASTIC GAS LINE MINIMUM 18 COVER. 2. 10LB MINIMUM GAS TEST. 3. ELECTRIC IS INCOMPLETE. 4. BOND WROUGHT IRON IF LESS THA 5 FEET FROM WATERS EDGE. 5. MAINTAIN MINIMUM 3 CLEARANCE REBAR TO DIRT.
04/04/2000 POOL/SPA PRE-GUNITE Denied IVRS - Inspection 0999*