Inspection History Details
Inspection Status: Not Ready
Inspection History: ENGR Engineering Final
Permit Number - DP21-0184
Inspection Description - ENGR Engineering Final
Inspection Status - Not Ready
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2022 | ENGR Engineering Final | Not Ready | ||
| 10/27/2022 | ENGR Engineering Final | Not Ready | ||
| 07/12/2022 | ENGR Engineering Final | BBENEDON | Partial Approval | Entered by NGARCIA3 - Partially approved. Engineering has no issues that would prevent occupying building is 2036. |
| 04/18/2024 | ENGR Engineering Final | Not Ready | Dale is the new superintendent on site for Caldwell construction. Please provide approved plan consult with project engineer if changes are necessary. | |
| 06/02/2023 | ENGR Engineering Final | Partial Pass | Building 16 | |
| 06/02/2023 | ENGR Engineering Final | Partial Pass | Building 16 is OK for TCO | |
| 06/06/2023 | ENGR Engineering Final | Complete (Recurring) | This project is on going | |
| 06/27/2023 | ENGR Engineering Final | Partial Pass | Building number 17 | |
| 07/03/2024 | ENGR Engineering Final | Not Ready | This permit covers the entire site, inspected today, 4/3/24 is address 2032. once the other 6 buildings are completed then the DP can be looked at to close out. | |
| 07/03/2024 | ENGR Engineering Final | Not Ready | This permit covers the entire site, inspected today, 4/3/24 is address 2032. once the other 6 buildings are completed then the DP can be looked at to close out. | |
| 08/08/2025 | ENGR Engineering Final | Failed | 1) pool area left side truncated domes more than a 2% cross slope right side of building 2) approach to pool gat more than a 2% cross slope 3) sidewalk in front of building heaved in accessible pathway. 4) left side truncated domes evidence of standing water. 5) 2036 evidence of standing water at truncated domes both locations 6) units 105 and 103 need a 60" x 60" landing per ADA required. 7) rail missing on drainage area walkway rear of building. 8) several areas where rocks are blocking drainage at sidewalk scuppers 9) 2026 & 2018 East side truncated domes evidence of standing water 10) 2018 north side rocks blocking downspout and grade lower at building 11) 2018 west side grade to low at northwest unit. 12) all sidewalk scuppers on west side are blocked. 13) rear of 2026 seams as dry wells have been installed, are these on plans? 14) 2010 west side downspout scupper blocked. 15) 2010 northwest corner truncated domes evidence to asphalt humped, ADA requires no more then a 1/4" deviation. 16) general all buildings, sewer clean outs throughout collars are not glued. 17) general all buildings, stripping is in bad shape as well is the general maintenance of the asphalt surface. Crack fill and seal coat is needed. |
|
| 08/16/2024 | ENGR Engineering Final | Not Ready | This site isn’t being constructed at this time currently working on the residences themselves not the clubhouse |