Permit: DP21-0029

Parcel: 132191450


Addresses:

2100 E AJO WY


Inspection Status: Passed

Inspection History: ENGR Grading Final

Permit Number - DP21-0029

Inspection Description - ENGR Grading Final

Inspection Status - Passed

Date Description Inspector Results Comments
07/25/2022 ENGR Grading Final DROBERTS Approved Entered by NGARCIA3 - APPROVED 2100 E AJO WY
07/25/2022 ENGR Grading Final DROBERTS Approved Entered by NGARCIA3 - APPROVED 2150 E AJO WY
06/17/2022 ENGR Grading Final DROBERTS Continued Entered by NGARCIA3 - CONTINUED AT THIS TIME, CREWS ARE WORKING AROUND THE SITE PERFORMING GRADING WORK AS NEEDED. THEY ARE ALSO WORKING ON GRADING THE PARKING LOT AND P.A.A.L.S FOR FUTURE PAVEMENT NEXT WEEK. 2150 E AJO WY
06/17/2022 ENGR Grading Final DROBERTS Continued Entered by NGARCIA3 - IS CONTINUED AT THIS TIME, CREWS ARE WORKING AROUND THE SITE PERFORMING GRADING WORK AS NEEDED. THEY ARE ALSO WORKING ON GRADING THE PARKING LOT AND P.A.A.L.S FOR FUTURE PAVEMENT NEXT WEEK. 2100 E AJO WY
06/09/2022 ENGR Grading Final DROBERTS Continued Entered by NGARCIA3 - CONTINUED, THE CREWS HAVE MADE SOME OF THE REQUIRED REPAIRS. WORK IS STILL NEEDED IN THE BASIN AREAS THROUGHOUT THE SITE TO ENSURE THE PROPER SIZING AND DEPTH. THE SIZING AND DEPTH IS IN QUESTION AT THIS TIME FOR THE BASINS LOCATED ON THE SOUTHERN AND EASTERN SIDES OF THIS PROJECT. THEY DO NOT APPEAR TO BE AS SHOWN ON THE APPROVED PLANS, VERIFICATION OF THE SIZING AND QUANTITY NEEDS TO BE CERTIFIED BY THE ENGINEER OF RECORD IF THEY ARE TO BE ACCEPTED IN THEIR CURRENT CONDITION. THE SMALLER BASIN AREAS ON THE NORTH PARKING LOT NEED TO BE REGRADED SO THEY HAVE THE MINIMAL DEPTHS AS NOTED ON THE APPROVED PLANS. THE DEPTHS WILL BE CHECKED TO VERIFY THAT THE BASIN BOTTOMS ARE AT LEAST 6 INCHES BELOW THE INLET IF THE STRUCTURE. 2150 E AJO WY
06/09/2022 ENGR Grading Final DROBERTS Continued Entered by NGARCIA3 - CONTINUED, THE CREWS HAVE MADE SOME OF THE REQUIRED REPAIRS. WORK IS STILL NEEDED IN THE BASIN AREAS THROUGHOUT THE SITE TO ENSURE THE PROPER SIZING AND DEPTH. THE SIZING AND DEPTH IS IN QUESTION AT THIS TIME FOR THE BASINS LOCATED ON THE SOUTHERN AND EASTERN SIDES OF THIS PROJECT. THEY DO NOT APPEAR TO BE AS SHOWN ON THE APPROVED PLANS, VERIFICATION OF THE SIZING AND QUANTITY NEEDS TO BE CERTIFIED BY THE ENGINEER OF RECORD IF THEY ARE TO BE ACCEPTED IN THEIR CURRENT CONDITION. THE SMALLER BASIN AREAS ON THE NORTH PARKING LOT NEED TO BE REGRADED SO THEY HAVE THE MINIMAL DEPTHS AS NOTED ON THE APPROVED PLANS. THE DEPTHS WILL BE CHECKED TO VERIFY THAT THE BASIN BOTTOMS ARE AT LEAST 6 INCHES BELOW THE INLET IF THE STRUCTURE. 2100 E AJO WY
05/20/2022 ENGR Grading Final DROBERTS Partial Approval Entered by VVERA1 - IS PARTIAL, COMPLETE ALL EXTERIOR WORK, ADDITIONAL INSPECTIONS WILL BE PERFORMED ON MONDAY
05/05/2022 ENGR Grading Final MHERNANDEZ Continued Entered by NGARCIA3 - CN / REBAR FOR THE GROUTING 2100 E Ajo Way
04/21/2022 ENGR Grading Final MHERNANDEZ Continued Entered by NGARCIA3 - CN REBAR INSPECTION FOR TRASH BIN FOOTER. 2100 E Ajo Way
07/25/2022 ENGR Grading Final DROBERTS Approved Entered by NGARCIA3 - APPROVED 2100 E AJO WY
07/25/2022 ENGR Grading Final DROBERTS Approved Entered by NGARCIA3 - APPROVED 2150 E AJO WY
06/21/2022 ENGR Grading Final MHERNANDEZ Continued Entered by NGARCIA3 - CN RE.FOR TH SCREEN WALL IN FRONT OF THE BUILDING.GOOD TO POUR THE FRIST 4’ 2150 E AJO WY
06/21/2022 ENGR Grading Final MHERNANDEZ Continued Entered by NGARCIA3 - CN RE.FOR TH SCREEN WALL IN FRONT OF THE BUILDING.GOOD TO POUR THE FRIST 4’ 2100 E AJO WY
06/17/2022 ENGR Grading Final DROBERTS Not ready for Inspection Entered by NGARCIA3 - IS NOT READY AT THIS TIME FOR THE SIGN FOOTERS FOR THE MENU BOARDS. THE CONTRACTOR WILL TAKE PHOTOS OF ALL THE FOOTERS ONCE THEY HAVE PLACED ADOBE BLOCKS ON THE EXTERIOR REBARS TO PROVIDE ADEQUATE CLEARANCE FROM THE EXTERIOR WALLS OF THE DRILLED HOLES. 2150 E AJO WY
06/17/2022 ENGR Grading Final DROBERTS Not ready for Inspection Entered by NGARCIA3 - NOT READY AT THIS TIME FOR THE SIGN FOOTERS FOR THE MENU BOARDS. THE CONTRACTOR WILL TAKE PHOTOS OF ALL THE FOOTERS ONCE THEY HAVE PLACED ADOBE BLOCKS ON THE EXTERIOR REBARS TO PROVIDE ADEQUATE CLEARANCE FROM THE EXTERIOR WALLS OF THE DRILLED HOLES. 2100 E AJO WY
08/08/2022 ENGR Grading Final DROBERTS Approved Entered by DROBERT5 -
08/08/2022 ENGR Grading Final DROBERTS Approved Entered by DROBERT5 -