Inspection History Details
Inspection Status: Passed
Inspection History: ENGR Grading Final
Permit Number - DP21-0029
Inspection Description - ENGR Grading Final
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/25/2022 | ENGR Grading Final | DROBERTS | Approved | Entered by NGARCIA3 - APPROVED 2100 E AJO WY |
07/25/2022 | ENGR Grading Final | DROBERTS | Approved | Entered by NGARCIA3 - APPROVED 2150 E AJO WY |
06/17/2022 | ENGR Grading Final | DROBERTS | Continued | Entered by NGARCIA3 - CONTINUED AT THIS TIME, CREWS ARE WORKING AROUND THE SITE PERFORMING GRADING WORK AS NEEDED. THEY ARE ALSO WORKING ON GRADING THE PARKING LOT AND P.A.A.L.S FOR FUTURE PAVEMENT NEXT WEEK. 2150 E AJO WY |
06/17/2022 | ENGR Grading Final | DROBERTS | Continued | Entered by NGARCIA3 - IS CONTINUED AT THIS TIME, CREWS ARE WORKING AROUND THE SITE PERFORMING GRADING WORK AS NEEDED. THEY ARE ALSO WORKING ON GRADING THE PARKING LOT AND P.A.A.L.S FOR FUTURE PAVEMENT NEXT WEEK. 2100 E AJO WY |
06/09/2022 | ENGR Grading Final | DROBERTS | Continued | Entered by NGARCIA3 - CONTINUED, THE CREWS HAVE MADE SOME OF THE REQUIRED REPAIRS. WORK IS STILL NEEDED IN THE BASIN AREAS THROUGHOUT THE SITE TO ENSURE THE PROPER SIZING AND DEPTH. THE SIZING AND DEPTH IS IN QUESTION AT THIS TIME FOR THE BASINS LOCATED ON THE SOUTHERN AND EASTERN SIDES OF THIS PROJECT. THEY DO NOT APPEAR TO BE AS SHOWN ON THE APPROVED PLANS, VERIFICATION OF THE SIZING AND QUANTITY NEEDS TO BE CERTIFIED BY THE ENGINEER OF RECORD IF THEY ARE TO BE ACCEPTED IN THEIR CURRENT CONDITION. THE SMALLER BASIN AREAS ON THE NORTH PARKING LOT NEED TO BE REGRADED SO THEY HAVE THE MINIMAL DEPTHS AS NOTED ON THE APPROVED PLANS. THE DEPTHS WILL BE CHECKED TO VERIFY THAT THE BASIN BOTTOMS ARE AT LEAST 6 INCHES BELOW THE INLET IF THE STRUCTURE. 2150 E AJO WY |
06/09/2022 | ENGR Grading Final | DROBERTS | Continued | Entered by NGARCIA3 - CONTINUED, THE CREWS HAVE MADE SOME OF THE REQUIRED REPAIRS. WORK IS STILL NEEDED IN THE BASIN AREAS THROUGHOUT THE SITE TO ENSURE THE PROPER SIZING AND DEPTH. THE SIZING AND DEPTH IS IN QUESTION AT THIS TIME FOR THE BASINS LOCATED ON THE SOUTHERN AND EASTERN SIDES OF THIS PROJECT. THEY DO NOT APPEAR TO BE AS SHOWN ON THE APPROVED PLANS, VERIFICATION OF THE SIZING AND QUANTITY NEEDS TO BE CERTIFIED BY THE ENGINEER OF RECORD IF THEY ARE TO BE ACCEPTED IN THEIR CURRENT CONDITION. THE SMALLER BASIN AREAS ON THE NORTH PARKING LOT NEED TO BE REGRADED SO THEY HAVE THE MINIMAL DEPTHS AS NOTED ON THE APPROVED PLANS. THE DEPTHS WILL BE CHECKED TO VERIFY THAT THE BASIN BOTTOMS ARE AT LEAST 6 INCHES BELOW THE INLET IF THE STRUCTURE. 2100 E AJO WY |
05/20/2022 | ENGR Grading Final | DROBERTS | Partial Approval | Entered by VVERA1 - IS PARTIAL, COMPLETE ALL EXTERIOR WORK, ADDITIONAL INSPECTIONS WILL BE PERFORMED ON MONDAY |
05/05/2022 | ENGR Grading Final | MHERNANDEZ | Continued | Entered by NGARCIA3 - CN / REBAR FOR THE GROUTING 2100 E Ajo Way |
04/21/2022 | ENGR Grading Final | MHERNANDEZ | Continued | Entered by NGARCIA3 - CN REBAR INSPECTION FOR TRASH BIN FOOTER. 2100 E Ajo Way |
07/25/2022 | ENGR Grading Final | DROBERTS | Approved | Entered by NGARCIA3 - APPROVED 2100 E AJO WY |
07/25/2022 | ENGR Grading Final | DROBERTS | Approved | Entered by NGARCIA3 - APPROVED 2150 E AJO WY |
06/21/2022 | ENGR Grading Final | MHERNANDEZ | Continued | Entered by NGARCIA3 - CN RE.FOR TH SCREEN WALL IN FRONT OF THE BUILDING.GOOD TO POUR THE FRIST 4’ 2150 E AJO WY |
06/21/2022 | ENGR Grading Final | MHERNANDEZ | Continued | Entered by NGARCIA3 - CN RE.FOR TH SCREEN WALL IN FRONT OF THE BUILDING.GOOD TO POUR THE FRIST 4’ 2100 E AJO WY |
06/17/2022 | ENGR Grading Final | DROBERTS | Not ready for Inspection | Entered by NGARCIA3 - IS NOT READY AT THIS TIME FOR THE SIGN FOOTERS FOR THE MENU BOARDS. THE CONTRACTOR WILL TAKE PHOTOS OF ALL THE FOOTERS ONCE THEY HAVE PLACED ADOBE BLOCKS ON THE EXTERIOR REBARS TO PROVIDE ADEQUATE CLEARANCE FROM THE EXTERIOR WALLS OF THE DRILLED HOLES. 2150 E AJO WY |
06/17/2022 | ENGR Grading Final | DROBERTS | Not ready for Inspection | Entered by NGARCIA3 - NOT READY AT THIS TIME FOR THE SIGN FOOTERS FOR THE MENU BOARDS. THE CONTRACTOR WILL TAKE PHOTOS OF ALL THE FOOTERS ONCE THEY HAVE PLACED ADOBE BLOCKS ON THE EXTERIOR REBARS TO PROVIDE ADEQUATE CLEARANCE FROM THE EXTERIOR WALLS OF THE DRILLED HOLES. 2100 E AJO WY |
08/08/2022 | ENGR Grading Final | DROBERTS | Approved | Entered by DROBERT5 - |
08/08/2022 | ENGR Grading Final | DROBERTS | Approved | Entered by DROBERT5 - |