Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Partial Pass
Inspection History: ENGR Paving
Permit Number - DP20-0060
Inspection Description - ENGR Paving
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/21/2025 | ENGR Paving | Partial Pass | 10/21/25 Drive through North of building. Elevations to survey. Subgrade compacted to over 95%. Depth are 7 inches. Slope is .5 away from building and .5 to the west and there is a break further east where it runs just over 1% downgrade to the west. Slope correct. There is a traffic rated grease interceptor and clean out that are a couple inches proud and concrete will slope up and transition smoothly to them. Cylinders will be taken and submitted to the portal along with compaction reports. Okay to pour drive through pending pictures of loose areas whacked down and smoothed. |
|
| 11/20/2025 | ENGR Paving | Partial Pass | I gave the contractor a partial pass. We strung line the Grade there was. some areas were high and other areas were low needs to re-grade it contractors would like to pave on Friday. contractor will call in for reinspection on Friday. |