Inspection History Details
Inspection Status: Complete (Recurring)
Inspection History: ENGR Grading Final
Permit Number - DP19-0058
Inspection Description - ENGR Grading Final
Inspection Status - Complete (Recurring)
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/19/2022 | ENGR Grading Final | BBENEDON | Continued | Entered by NGARCIA3 - Continue |
| 06/23/2022 | ENGR Grading Final | BBENEDON | Continued | Entered by NGARCIA3 - Continued. The City approved construction documents for this expired permit with an engineering final inspection only shows the majority of the site work requirements to be completed including landscaped area south of The Project along the north bank of the wash. |
| 04/05/2022 | ENGR Grading Final | DROBERTS | Continued | Entered by NGARCIA3 - IS CONTINUED, MET WITH THE ENGINEER OF RECORD AND THE CONTRACTOR FOR THE POSSIBILITY OF GETTING A TCO FOR THE 1ST FLOOR. DUE TO THAT NONE OF THE PARKING HAS NOT BEEN CONSTRUCTED AT THIS TIME IT IS DENIED. 1) THEY WILL HAVE TO PROVIDE 2 ADA ACCESSIBLE PARKING SPACES AND AN ACCESSIBLE ROUTE TO THE FIRST FLOOR ENTRANCE. 2) ALSO THEY WILL NEED TO PROVIDE ONE REGULAR PARKING SPACE FROM AN OUTER PARKING AREA INTO THE STRUCTURE. 3) CLEAR ALL AREAS AND PASSAGE WAYS WITHIN THE STRUCTURE THAT CONTAIN CONSTRUCTION TRASH, DEBRIS, EXCESS MATERIAL, OR ANYTHING THAT MAY CREATE A HEALTH AND SAFETY ISSUE FOR PEDESTRIANS. THE CONTRACTOR FEELS THAT SINCE HE IS NOT OPENING ANY OF THE UNITS THAT ARE GOING TO BE UTILIZED BY SOMEONE WHO IS HANDICAPPED, IT IS UNFAIR TO WITH HOLD THE TCO. HE WAS ADVISED THAT EVEN THOUGH THEY MAYNOT BE OPENING THOSE AREAS YET, WE CANNOT EXCLUDE THE HANDICAP REQUIREMENTS AT THIS TIME EITHER. ALSO NOTED DURING THIS INSPECTION THE FOLLOWING ITEMS STILL NEED TO BE ADDRESSED: COMPLETE ALL NATURAL SLOPES THAT APPEAR TO BE EXCESSIVE WITH THE CURRENT GRADES ON THE SLOPES(LESS THAN 3:1 OR STEEPER)PAVING, LANDSCAPING, DRAINAGE OPENINGS AND CHANNELS, ROOF DRAINAGE OPENINGS BENEATH THE STRUCTURE INTO THE EXISTING CHANNEL. ALL THE ABOVE ITEMS WILL BE CHECKED AND ADDRESSED PRIOR TO CLEARING THE CONCERNED ITEMS LISTED ON THE PERMIT. |
| 05/27/2021 | ENGR Grading Final | BBENEDON | Continued | Entered by VLEON1 - Continued. This project is running concurrent with DP19 Dash 0187. Construction in progres |