07/10/2019 | COT - ENGR - Signage Final | BBENEDON | Approved | Entered by DMERANZ1 - |
06/27/2019 | COT - ENGR - Signage Final | BBENEDON | Not ready for Inspection | Entered by DMERANZ1 - Contractor wanting to confirm that a sidewalk scupper Will be acceptable to mitigate the drainage issue over the accessible sidewalk and ramp at the main entrance. Also wanting to confirm that a letter from the engineer for the dumpster enclosure built without inspection is required. |
06/18/2019 | COT - ENGR - Signage Final | BBENEDON | Not ready for Inspection | Entered by DMERANZ1 - One accessible space requires correction. Sidewalks are OK. Provide revisions for all changes made including accessible routes. Rainwater may not train over accessible walkways. Bicycle parking has not been installed. The trashing closure is less than 6 feet tall and was not inspected by engineering. Provide a letter from your engineer stating that the enclosure was constructed in accordance with COT standard detail 6.01. Correct the doors that do not open fully, drill pinholes in concrete. Provide a letter certifying final grade. Install the missing trees and complete all landscaping. Clean all construction materials and debris’s. Complete installation of signs |
06/17/2019 | COT - ENGR - Signage Final | BBENEDON | Not ready for Inspection | Entered by DMERANZ1 - The work has not been completed at this time |