Permit: DP18-0272

Parcel: 11811007B


Addresses:

709 W SILVERLAKE RD


Inspection Status: Passed

Inspection History: ENGR Engineering Final

Permit Number - DP18-0272

Inspection Description - ENGR Engineering Final

Inspection Status - Passed

Date Description Inspector Results Comments
08/23/2019 ENGR Engineering Final BBENEDON Approved Entered by DMERANZ1 -
08/14/2019 ENGR Engineering Final BBENEDON Not ready for Inspection Entered by DMERANZ1 - Daniel at 210-278-4163 will complete the fence and provide the required documentation, and will reschedule for inspection when ready.
07/11/2019 ENGR Engineering Final BBENEDON Not ready for Inspection Entered by DMERANZ1 - I spoke with the general contractor at 210-844-6272. We discussed the final corrections previously noted and I informed him that several of the catch basin‘s still have Plastic covering the openings.
06/27/2019 ENGR Engineering Final BBENEDON Not ready for Inspection Entered by DMERANZ1 - Contractor wanting to confirm that a sidewalk scupper Will be acceptable to mitigate the drainage issue over the accessible sidewalk and ramp at the main entrance. Also wanting to confirm that a letter from the engineer for the dumpster enclosure built without inspection is required.
05/28/2019 ENGR Engineering Final BBENEDON Partial Approval Entered by CBELL1 - Engineering has no issues that would prevent a TCO
05/15/2019 ENGR Engineering Final BBENEDON Not ready for Inspection Entered by DMERANZ1 - Contractor is performing final grading and installing curbs. Access to the building will be required for A TCO
08/23/2019 ENGR Engineering Final BBENEDON Approved Entered by DMERANZ1 -
08/14/2019 ENGR Engineering Final BBENEDON Not ready for Inspection Entered by DMERANZ1 - Daniel at 210-278-4163 will complete the fence and provide the required documentation, and will reschedule for inspection when ready.
07/17/2019 ENGR Engineering Final BBENEDON Not ready for Inspection Entered by DMERANZ1 - A sinkhole has started to form in the basin along the road, in the southeast parking area. Visqueen is still covering the inlet structure in the southeast corner basin One tree is falling over along the south property line.
07/11/2019 ENGR Engineering Final BBENEDON Not ready for Inspection Entered by DMERANZ1 - I spoke with the general contractor at 210-844-6272. We discussed the final corrections previously noted and I informed him that several of the catch basin‘s still have Plastic covering the openings.
06/27/2019 ENGR Engineering Final BBENEDON Not ready for Inspection Entered by DMERANZ1 - Contractor wanting to confirm that a sidewalk scupper Will be acceptable to mitigate the drainage issue over the accessible sidewalk and ramp at the main entrance. Also wanting to confirm that a letter from the engineer for the dumpster enclosure built without inspection is required.
06/18/2019 ENGR Engineering Final BBENEDON Not ready for Inspection Entered by DMERANZ1 - One accessible space requires correction. Sidewalks are OK. Provide revisions for all changes made including accessible routes. Rainwater may not train over accessible walkways. Bicycle parking has not been installed. The trashing closure is less than 6 feet tall and was not inspected by engineering. Provide a letter from your engineer stating that the enclosure was constructed in accordance with COT standard detail 6.01. Correct the doors that do not open fully, drill pinholes in concrete. Provide a letter certifying final grade. Install the missing trees and complete all landscaping. Clean all construction materials and debris’s. Complete installation of signs
06/17/2019 ENGR Engineering Final BBENEDON Not ready for Inspection Entered by DMERANZ1 - Superintendent not on site, could not locate plans. Work is being completed on the north and west areas of the site and across the street in the parking areas. The ADA parking to the south exceeds 2% maximum cross slope also we have one section of accessible walkway coming from Street to the east that Exceeds 2% cross slope. Complete all work make corrections as needed, and re-call for inspections