Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: DP18-0082

Parcel: 136048090

Inspection Status: Passed

Inspection History: ENGR Engineering Final

Permit Number - DP18-0082

Inspection Description - ENGR Engineering Final

Inspection Status - Passed

Date Description Inspector Results Comments
02/08/2021 ENGR Engineering Final DROBERTS Approved Entered by VLEON1 - APPROVED
02/05/2021 ENGR Engineering Final DROBERTS Partial Approval Entered by DROBERT5 - PARTIAL AT THIS TIME, OK FOR A TCO FOR THE COMBO PERMIT, COMPLETE ALL WORK ON THIS SITE AND PROVIDE ALL DOCUMENTATION
02/11/2021 ENGR Engineering Final DROBERTS Approved Entered by DROBERT5 -
02/08/2021 ENGR Engineering Final DROBERTS Continued Entered by VLEON1 - COMPLETE REMAINING WORK . 1) INSTALL THE SIDEWALK ON THE WEST SIDE OF THE PARKING LOT EAST OF THE OPEN PAD. 2) INSTALL THE DECOMPOSED GRANITE/HYDRO-SEED MIX ONTO THE OPEN PAD AREA WHERE THERE IS DISTURBED SOIL. 3) CONSTRUCT THE NEW RETAINING WALL ON THE EAST SIDE OF THE NEW BUILDING WHERE THE SLOPES ARE LESS THAN 2:1 OR 1:1 AS PREVIOUSLY DISCUSSED WITH THE ENGINEER OF RECORD. 4) PROVIDE THE REQUIRED CLOSEOUT DOCUMENTATION FOR THIS SITE, ENGINEERING AND ZONING APPROVED REVISED DRAWINGS FOR ALL CHANGES THAT HAVE BEEN MADE TO THIS SITE TO BE UTILIZED FOR THE FINAL GRADING INSPECTION, CERTIFICATION LETTER FROM THE ENGINEER OF RECORD FOR THIS SITE, PRIOR TO SCHEDULING THIS SITE FOR THE FINAL GRADING INSPECTION.
02/05/2021 ENGR Engineering Final DROBERTS Continued Entered by DROBERT5 - COMPLETE ALL WORK ON THIS SITE AS SHOWN ON THE APPROVED PLANS OR PROVIDE APPROVED REVISED DRAWINGS FOR ALL CHANGES THAT HAVE BEEN MADE TO THIS SITE. COMPLETE THE MISSING SIDEWALK ON THE WEST SIDE OF THE PARKING LOT ADJACENT TO THE BLANK PAD LOCATED AT THE SOUTHWEST CORNER OF THIS SITE.
01/06/2021 ENGR Engineering Final MHERNANDEZ Continued Entered by VLEON1 -