Inspection History Details
Inspection Status: Passed
Inspection History: ENGR Engineering Final
Permit Number - DP17-0157
Inspection Description - ENGR Engineering Final
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/18/2019 | ENGR Engineering Final | DROBERTS | Approved | Entered by CBELL1 - |
03/07/2019 | ENGR Engineering Final | BBENEDON | Not ready for Inspection | Entered by CBELL1 - The depressed landscaped areas shown on page 15 do not appear to be depressed to the extent shown on the plan, in addition the depressed area on the south side of the building is higher than the drain pipe outlet and rip rap Areas at the drain pipe outlet still retain water for several days after the rain according to the security guard on site. In addition there is mud caked on the bottom of the riprap to indicate this. I have seen no letter certifying grade or elevations. The dirt area of phase 2 does not appear to have been stabilized. There is some Dirt in the Southern most parking spaces |
02/08/2019 | ENGR Engineering Final | BBENEDON | Partial Approval | Entered by CBELL1 - Pedestrian striping has been completed Superintendent is not on site, I left my phone number on his desk. Work is ongoing, landscapers are hard at it, job trailer dumpsters, toilets are still on site. There is dirt and other debris that still needs to be cleaned up |
02/07/2019 | ENGR Engineering Final | BBENEDON | Partial Approval | Entered by CBELL1 - Engineering inspection has no issues preventing a temporary CFO for development package. A letter certifying the site grading may be required. Revisions for all changes made. Complete walkway striping. Provided stabilization at phase 2 area. Correct cross slope of DG walkwayIn locations identified. We have standing water into accessible parking spaces on the north side of the property. We have standing water at the grouted riprap areas. Water harvesting areas are not depressed as shown on plan. Note there is water that is not draining from these areas after 24 hours. Complete all landscaping, steak the trees etc. Note the slope of the parking spaces concrete and asphalt paths are OK |
11/20/2018 | ENGR Engineering Final | RLEDONNE | Not ready for Inspection | Entered by CBELL1 - complete all work on approved plans for engineering final. |
04/18/2019 | ENGR Engineering Final | DROBERTS | Approved | Entered by DROBERT5 - |
03/07/2019 | ENGR Engineering Final | BBENEDON | Not ready for Inspection | Entered by CBELL1 - The depressed landscaped areas shown on page 15 do not appear to be depressed to the extent shown on the plan, in addition the depressed area on the south side of the building is higher than the drain pipe outlet and rip rap Areas at the drain pipe outlet still retain water for several days after the rain according to the security guard on site. In addition there is mud caked on the bottom of the riprap to indicate this. I have seen no letter certifying grade or elevations. The dirt area of phase 2 does not appear to have been stabilized. There is some Dirt in the Southern most parking spaces |
02/08/2019 | ENGR Engineering Final | BBENEDON | Not ready for Inspection | Entered by CBELL1 - |
02/07/2019 | ENGR Engineering Final | BBENEDON | Not ready for Inspection | Entered by CBELL1 - |