Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Not Ready
Inspection History: ENGR Engineering Final
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/2022 |
ENGR Engineering Final
|
|
Not Ready |
|
| 09/22/2020 |
ENGR Engineering Final
|
DROBERTS |
Approved |
Entered by DROBERT5 - SEE ITEMS IN GRADING FINAL FOR ALL NEEDED WORK |
| 10/15/2020 |
ENGR Engineering Final
|
DROBERTS |
Not ready for Inspection |
Entered by RSALDAT1 - IS NOT READY AT THIS TIME, SEE PREVIOUS COMMENTS FOR NECESSARY REPAIR WORK THAT NEEDS TO BE COMPLETED PRIOR TO FINAL ACCEPTANCE. |
| 09/22/2020 |
ENGR Engineering Final
|
DROBERTS |
Partial Approval |
Entered by RSALDAT1 - IS PARTIAL AT THIS TIME. PREVIIUSLY NOTED SIDEWALK NORTH AND AT THE NORTHWEST CORNER OF LOT #38 IS NONCOMPLIANT FOR ADA, CROSS SLOPE EXCEEDS MAXIMUM 2%. TO CLOSE THIS SITE OUT COMPLETE THE REMAINING WORK AND PROVIDE ALL CLOSEOUT DOCUMENTATION: APPROVED REVISED DRAWINGS, CETIFICATION LETTER FROM THE ENGINEER OF RECORD, AND A COPY OF THE NOTICE OF TERMINATION FOR THE SWPPP FOR THIS SITE. |
| 07/16/2020 |
ENGR Engineering Final
|
BBENEDON |
Partial Approval |
Entered by JSCHNEI2 - Partially approved. Project appears to be complete. Some of the landscaping areas were not depressed as shown however basins appear to be properly built and in good condition.
|