Inspection Status: Passed
Inspection History: SITE - Stormwater Setup and Controls
Permit Number - DP15-0060
Inspection Description - SITE - Stormwater Setup and Controls
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/23/2015 | SITE - Stormwater Setup and Controls | RLEDONNE | Approved | Entered by RLEDONN1 - |
04/29/2015 | SITE - Stormwater Setup and Controls | DROBERTS | Partial Approval | Entered by DROBERT5 - NOTIFIED THE CONTRACTOR THAT HE NEEDS TO INSTALL ALL THE SWPPP MATERIAL CORRECTLY AS SHOWN ON HIS APPROVED PLANS. THE WATTLE NEEDS TO BE LAID IN A DEPRESSED AREA AND THEN STAKED ACCORDINGLY. CURRENTLY THE WATTLE IS BEING PLACED DIRECTLY ONTOP OF THE GRADE, AND THE STAKES ARE NOT PENETRATING INTO THE GROUND AT ALL LOCATIONS.I HAVE ASKED THAT THEY CREWS REWORK THE AREA ADJACENT TO THE WASH TO ENSURE THAT WE DO NOT HAVE ANY CONTAMINATION OF THE WASH FROM THIS SITE. THE CREW WILL MAKE THE NECESSARY CHANGES ALONG THE WASH, THE OUTER AREAS ON THE SOUTHERN WILL HAVE THE WALL FOOTER EXCAVATIONS START NEXT WEEK. |