Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: DP14-0177

Parcel: Unknown


Addresses:

9455 E VALENCIA RD

Inspection Status: Passed

Inspection History: PDSD Site/Engineering Division - Landscaping

Date Description Inspector Results Comments
04/11/2016 PDSD Site/Engineering Division - Landscaping MRUSSO Approved Entered by MRUSSO1 -
03/03/2015 PDSD Site/Engineering Division - Landscaping MRUSSO Continued Entered by DROBERT5 - CORRECTION REQUIRED: 1) INSTALL SEDIMENT CONTROLS PER YOUR SWPPP 2) POST A COPY OF YOUR NOI AT ENTRANCE 3) INSTALL A STABIZED CONSTRUCTION ENTRANCE/EXIT 4) INSTALL A CONCRETE/MATERIALS WASH OUT 5) PROVIDE A MONITORING REPORT FROM THE LANDSCAPE ARCHITECT CORRECT WITH IN 10 WORKING DAYS
02/18/2015 PDSD Site/Engineering Division - Landscaping MRUSSO Continued Entered by DROBERT5 - 1) MET WITH PROJECT MANAGER, REVIEWED PLANS AND WALKED SITE. 2) CONTRACTOR HAS STARTED IMPLEMENTING NPPO. PLANTS HAVE BEEN TAGGED AND IDENTIFIED. 3) A NUSERY WILL BE ESTABLISHED AND PLANTS WILL BE MOVED. 4) ENSURE YOUR STORM WATER PLAN IS IMPLEMENTED PRIOR TO GRUBBING AND GRADING. 5) CALL FOR RE-INSPECTION FOR QUESTIONS AND/OR CONCERNS