Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: DP14-0044

Parcel: 10707014B

Inspection Status: Passed

Inspection History: ENGR Engineering Final

Permit Number - DP14-0044

Inspection Description - ENGR Engineering Final

Inspection Status - Passed

Date Description Inspector Results Comments
04/22/2020 ENGR Engineering Final DROBERTS Approved Entered by DROBERT5 - THESE APPEAR TO HAVE BEEN COMPLETED PER THE APPROVED PLANS.
08/03/2016 ENGR Engineering Final MRUSSO Continued Entered by MRUSSO1 - AWAITING FINAL INSPECTION
07/28/2016 ENGR Engineering Final MRUSSO Continued Entered by MRUSSO1 - 1) CALL FOR FINAL GRADING INSPECTION FOR PERMIT# DP14-0044 2) PROVIDE A CERT STATEMENT FROM THE ENG OF RECORD 3) PROVIDE AN AS-BUILT DRAWING FOR THE FINAL INSPECTION, SHOWING APPROVED CHANGES MADE TO THE SITE.
04/11/2016 ENGR Engineering Final MRUSSO Prior to Final Inspectn Entered by MRUSSO1 - 1) PROVIDE COPIES OF YOUR STORM WATER SELF INSPECTIONS REQUIRED BY YOUR PERMIT 2) CONTRCTOR INSTALLING SECTIONS OF 24" CMP TO CONNECT TO EAST CATCH BASIN. 3) CONTRACTOR RE-INSTALLING CENTER CATCH BASIN - CALL FOR INSPECTION WHEN FORMED. 4) ENSURE STORM PIPE SLOPE IS AT 0.5% OR GREATER. 5) ENSURE YOUR SWPPP AND NOI ARE ON SITE DURING CONSTRUCTION SITE IS IN NON-COMPLIANCE WITH THIER STORM WATER PERMIT. A CERTIFICATION LETTER FROM THE ENG OF RECORD IS REQUIRED PRIOR TO FINAL APPROVAL