Permit: DP13-0163

Parcel: 13014447A


Addresses:

1305 S ALVERNON WY


Inspection Status: Passed

Inspection History: SITE - Stormwater Setup and Controls

Permit Number - DP13-0163

Inspection Description - SITE - Stormwater Setup and Controls

Inspection Status - Passed

Date Description Inspector Results Comments
02/06/2014 SITE - Stormwater Setup and Controls MRUSSO Approved Entered by DROBERT5 - 1) CONTRACTOR COMPLETED INSTALLATION OF STORM WATER CONTROLS PER PLAN 2) ENSURE CONTROLS ARE MAINTAINED THROUGHOUT CONSTR 3) CONTRACTOR STARTED WORK ON INSTALL OF STORM WATER DRAINAGE PIPE - PICS TAKEN 4) NO SIGNIFICANT STORM WATER COCERNS AT THIS TIME
01/28/2014 SITE - Stormwater Setup and Controls MRUSSO Partial Approval Entered by DROBERT5 - 1) INSTALL SEDIMENT CONTROLS PER YOUR SWPPP 2) MAINTAIN CONTROLS THROUGHOUT CONSTRUCTION 3) ENSURE YOU PERFORM YOUR STORM WATER SELF INSPECTIONS PER PLAN AND DOCUMENT THEM 4) SWEEP UP ANY TRACKED SOIL FROM OFF SITE ROUTINELY 5) POST A SIGNED COPY OF YOUR NOI AT THE ENTRANCE TO THE SITE 6) INSTALL A CONCRETE/MATERIALS WASH OUT ON SITE CALL FOR ANY SITE/GRADING CONCERNS OR CHANGES