Inspection History Details
Inspection Status: Passed
Inspection History: ENGR Engineering Final
Permit Number - DP13-0149
Inspection Description - ENGR Engineering Final
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/02/2016 | ENGR Engineering Final | MRUSSO | Approved | Entered by MRUSSO1 - |
12/01/2016 | ENGR Engineering Final | MRUSSO | Cancelled | Entered by MRUSSO1 - |
11/17/2016 | ENGR Engineering Final | MRUSSO | Continued | Entered by MRUSSO1 - 1) PROVIDE A CERTIFICATION STATEMENT FROM THE ENGINEER OF RECORD, DUE TO THE SIGNIFICANT CHANGES MADE TO THE GRADING PLAN 2) INSTALL GATES ON TRASH ENCLOSURE PER APPROVED PLANS |
10/25/2016 | ENGR Engineering Final | DROBERTS | Partial Approval | Entered by DROBERT5 - SITE NOT READY AT THIS TIME, A REINSPECTION OF THE SITE WILL BE PERFORMED LATER THIS WEEK. |
10/24/2016 | ENGR Engineering Final | MRUSSO | Continued | Entered by MRUSSO1 - NO CONTACT |
07/28/2016 | ENGR Engineering Final | MRUSSO | Continued | Entered by MRUSSO1 - PROVIDE AN APPROVED PLAN THAT SHOWS SITE/GRADING/ AND LANDSCAPING THAT WAS CONSTRUCTED |
07/21/2016 | ENGR Engineering Final | MRUSSO | Continued | Entered by MRUSSO1 - 1) PRIOR TO FINAL APPROVAL BY ENGINEERING, PROVIDE A CERT LETTER FROM THE ENG OF RECORD, PER YOUR APPROVED PLANS 2) PROVIDE AN APPROVED AS-BUILT DRAWING SHOW ANY AND ALL CHANGES MADE. 3) ENSURE ADA ACCESS AND PARKING MEET REQUIREMENTS 4) ADD RETAINING WALLS TO PLANS AND PROVIDE SPECIAL INSPECTION RESULTS 5) ADD SCUPPERS WHERE ROOF DRAINS DROP ONTO SIDEWALKS 6) ENSURE SITE ELEVATIONS ARE SHOWN ON THE APPROVED PLANS. |