Inspection Status: Passed
Inspection History: PDSD Engineering Division Pre-Construction SITE
Permit Number - DP13-0072
Inspection Description - PDSD Engineering Division Pre-Construction SITE
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2013 | PDSD Engineering Division Pre-Construction SITE | MRUSSO | Approved | Entered by DROBERT5 - 1) INSTALL SEDIEMNT CONTROLS PER YOUR SWPPP. USE EXISTING BARRIERS IF POSSIBLE, CALL FOR APPROVAL 2) POST A SIGNED COPY OF YOUR NOI AT THE ENTRANCE TO THE SITE. 3) CALL FOR NPPO APPROVAL WHEN COMPLETED. 4) PROTECT EXISTING CATCH BASINS AND CULVERTS FROM CONSTRUCTION SOIL RUN-OFF 5) SWEEP UP TRACKED SOIL ROUTINELY. 6) INSTALL A STABILIZED CONSTRUCTION ENTRANCE PER PLAN 7) INSTALL A CONCRETE/MATERIALS WASH OUT ON SITE WHEN APPLICABLE. 8) PERFORM STORM WATER SELF INSPECTIONS PER PLAN AND DOCUMENT THEM 9) CALL FOR INSPECTION PRIOR TO COVERIN NEW STORM PIPE AND/OR CULVERTS |