Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Passed
Inspection History: ENGR Engineering Final
| Date |
Description |
Inspector |
Results |
Comments |
| 08/05/2020 |
ENGR Engineering Final
|
DROBERTS |
Approved |
Entered by DROBERT5 - |
| 05/02/2018 |
ENGR Engineering Final
|
MRUSSO |
Continued |
Entered by DROBERT5 - NOTES FROM 2014 INSPECTION BY DAVE ROBERTS:
CONTACTED THE ENGINEER OF RECORD AND HAVE ASKED THAT HE PROVIDE APPROVED AS-BUILT DRAWINGS FOR ALL CHANGES THAT HAVE BEEN MADE TO THIS SITE. |
| 01/23/2014 |
ENGR Engineering Final
|
DROBERTS |
Continued |
Entered by DROBERT5 - THIS SITE WILL NEED TO HAVE THE CURB SECTION REMOVED FROM THE DRIVEWAY LOCATED AT THE SOUTHEAST CORNER OF THE SITE AND NEW CURB RE-POURED AS NOTED IN NOTE 33 OF THE DEMOLITION PLAN. THE EXISTING DRIVEWAY APRON SHOWN IN NOTE 1 ON PAGE 2 OF 4 IS INCORRECT. THE CURRENT CONDITIONS DO NOT MEET THE CURRENT ADA ACCESSIBILITY STANDARDS, THIS AREA WILL HAVE TO BE REMOVED AND NEW SIDEWALK WILL HAVE TO BE PLACED TO COMPLETE THE REQUIRED PEDESTRIAN ACCESS AREAS. REVISED/AS-BUILT DRAWINGS FOR THIS SITE NEED TO BE SUBMITTED ALONG WITH A LETTER OF CERTIFICATION TO BE REVIEWED AND APPROVED BEFORE THE FINAL INSPECTION OF THIS SITE CAN BE COMPLETED. FEEL FREE TO CONTACT DAVID ROBERTS AT ANY TIME AT 520-349-7643 IF YOU HAVE ANY QUESTIONS ABOUT THIS INSPECTION. |
| 01/07/2014 |
ENGR Engineering Final
|
MRUSSO |
Continued |
Entered by DROBERT5 - 1) NO CHANGES, NO INSPECTION CALLED IN.
2) PRIOR TO FINAL APPROVAL, PROVIDE A CERT STATEMENT FROM THE ENG OF RECORD IN ORDER TO VERIFY THAT CONSTRUCTION WAS COMPLETED PER THE APPROVED PLANS DUE TO THE FACT THAT NO SITE INSPECTIONS WERE DONE |