Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.
Inspection Status: Passed
Inspection History: ENGR Grading Final
| Date |
Description |
Inspector |
Results |
Comments |
| 11/13/2013 |
ENGR Grading Final |
RLEDONNE |
Approved |
Entered by ARUIZ1 - |
| 11/13/2013 |
ENGR Grading Final |
RLEDONNE |
Approved |
Entered by ARUIZ1 - |
| 11/13/2013 |
ENGR Grading Final |
RLEDONNE |
Approved |
Entered by ARUIZ1 - |
| 10/31/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - GC NOT ON SITE . TO GO OVER WORKFOR FINAL. |
| 10/28/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - NO ACTIVITY ON SITE. |
| 10/10/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - GOT WITH GC ABOUT CERT LETTER FOR ALL GRADING AND DRAINAGE. |
| 10/09/2013 |
ENGR Grading Final |
eleibol1 |
Continued |
Entered by ELEIBOL1 - Report from Ken Perry at ES, who stated that his field trip found that trash enclosures were accepted for solid waste pick-up for Shops A2, B3, B4, & H. Ken reiterated that future projects will need 10 by10-ft clear inside bollards, a couple of feet of offset from front corner of trash enclosure where parking is to the side/front to avoid potential clipping of cars, no woven wire mesh should be accepted (gates need to be opaque, 40-ft approach should be straight & clear of curbs or other obstructions, enclosure area & approach area shall not be in a stormwater flow line and have minimum 2% grade for postive gradient for flows to flow away from enclosure. |
| 09/09/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - WALKED SITE WITH DAVE GOT WITH CONTRACTOR ABOUT INSTALLING BIKE PARKING . AND PROVIDE LETTER TASH ENCLOSURE. |
| 09/05/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - NO CHANGE TO TRASH ENCLOSURE. |
| 08/28/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - GRADING CONTRACTOR STABILIZATED DISTURBED AREA. |
| 08/27/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - FINAL GRADING FOR STABILZATION ON AREA OFF SITE. |
| 08/06/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - NO ACTIVTY OUT BUILDINGS. |
| 08/01/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - NO CONCERNS AT THIS TIME. |
| 07/16/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - GOT WITH GC ABOUT PALS IN PARKING AREA AT PAD H. |
| 07/02/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - FINAL GRADING WORK AROUND BUILDING. ON PAD A-2. |
| 07/01/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - STRADED PAVING WORK ON PAD A-3. |
| 06/10/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - ALL CATCH BASINS COMPLET. |
| 06/07/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - PAD H TRASH ENCLOURES 10 BY 10 . |
| 06/06/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - WORKING ON CURBS . AND BACK FILLING. |
| 05/29/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - PAD B-3 WORKING ON STORM PIPING AND BASINS . |
| 05/28/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - FORMING CATCH BASIN ON WEST SIDE OF SITE. AT PAD B-3. |
| 05/23/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - BOTTOM OF CATCH BASIN ONLY. |
| 05/22/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - INSPECTION PER HIGH LIGHTS ON PAGE G-4. |
| 05/20/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - PAD B-3 PER HIGH LIGHT ON PAGE G4FOR STROM DRAIN PIPING. |
| 05/15/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - CURB WORK ON PAD H. NO TRACK OUT AT THIS TIME. |
| 04/30/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - ADD CONTROLS AT CATCH BASINS . FOR A-2 PAD AND H PAD. |
| 04/23/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - PADS H& A-2 WORKING ON WATER MAINS ONLY AT THIS TIME. |
| 04/08/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - NO ACTIVITY ON PAD A-2 OR PAD H. |
| 04/05/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - GOT WITH GC ABOUT SWPPP INFO FOR PAD H .AND PROVIDE SWPPP CONTROLS AT NEW BASINS FOR PADS H & A-2. |
| 04/01/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - WORKING ON CATCH BASIN ON NORTH EAST SIDE OF PAD H. WORKING ON STROMDRAIN MANHOLE AT PAD A-2. |
| 03/29/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - INSPECTOIN FOR PAD A-2 PAGE G-3 PER HIGH LIGHT. BASIN INPECTION FOR PAD H PER HIGH LIGHT ON PAGE G-5. |
| 03/28/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - THIS INSPECTION IS FOR SITE H INSPECTION PER HIGH LIGHT ON PAGE C-5. |
| 03/13/2013 |
ENGR Grading Final |
RLEDONNE |
Continued |
Entered by RLEDONN1 - WORKING ON SITE SEWER. NO TRACK OUT OR GRADING ACTIVITY. |