04/12/2013 | ENGR Engineering Final | DROBERTS | Continued | Entered by DROBERT5 - CONTACTED THE ENGINEER OF RECORD THEODORE C. MOELLER WITH GLHN ARCHITECTURE AND ENGINEERING INC. AND ADVISED HIM OF THE MISSING ITEMS FOR THIS SITE. HE WILL ASK THAT HIS CIVIL ENGINEER TOO LOOK AT THE SITE AND ADDRESS THE ISSUES AT A LATER DATE. |
04/11/2013 | ENGR Engineering Final | DROBERTS | Continued | Entered by DROBERT5 - SITE APPEARS TO BE COMPLETE ON MOST OF THE ITEMS BUT FALLS SHORT IN THE FOLLOWING 2 AREAS: 1) POINT #134 ON SHEET NUMBER CS101 CALLS FOR A NEW WATER FOUNTAIN TO BE INSTALL IN AN AREA SOUTH OF THE NEW CANOPYS. 2) 6 PARKING SPACES APPEAR TO BE MISSING IN THE PARKING AREA ON THE NORTHSIDE OF THE FACILITY WEST OF THE NEW HANDICAP PARKING SPACES. |
04/09/2013 | ENGR Engineering Final | DROBERTS | Continued | Entered by DROBERT5 - SITE PAPERWORK NEED FOR THE CLOSURE OF THE PERMIT, INSPECTION TO BE PERFORMED ON 4/10/2013. |