Inspection Status: Passed
Inspection History: SITE - Stormwater Setup and Controls
| Date |
Description |
Inspector |
Results |
Comments |
| 05/15/2013 |
SITE - Stormwater Setup and Controls |
MRUSSO |
Approved |
Entered by DROBERT5 - |
| 03/12/2013 |
SITE - Stormwater Setup and Controls |
MRUSSO |
Partial Approval |
Entered by DROBERT5 - 1) PERIMETER SILT SOCK HAS BEEN INSTALLED PER SWPPP
2) A STABILIZED CONSTRUCTION ENTRANCE HAS BEEN INSTALLED.
3) SUPPLEMENTAL SEDIMENT CONTROLS MADE NEED TO BE INSTALLED WHEN UTILITIES ARE BROUGHT ACROSS THE WASH FROM THE NW CORNER.
4) INSTALL A CONCRETE/MATERIALS WASH OUT AS SOON AS PACTICABLE.
5) CALL FOR RE-INSPECTION |