Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 10605069A


Addresses:

744 W SIMMONS RD


Inspection Status: In Violation

Inspection History: COT - ENFC - Code Enforcement - Initial

Case Number - CE-VIO1224-05046

Inspection Description - COT - ENFC - Code Enforcement - Initial

Inspection Status - In Violation

Date Description Inspector Results Comments
12/27/2024 COT - ENFC - Code Enforcement - Initial In Violation There is trash and debris on the property. There is furniture, appliances and other miscellaneous items being stored in the front yard, side, and rear yard. There is an inoperable Isuzu Rodeo with flat tires on the property. The mobile home has multiple damaged windows not protecting the interior or their occupants from the weather. There is an approximate 14ft wide by 50 ft long carport attached to the mobile home without permits or zoning approvals. This carport has 2x4 rafters spanning the full width of 14ft. The support post are wooden 4x4 posts and alternating metal scroll posts. The beam supporting the carport’s decking is a wood 4x6, however the beam has been installed that the 6 inches is the width, and the 4 inches is the height. The carports decking is damaged and in need of replacement for it has open penetrations. The height of the carport (approximately 10ft) may be encroaching the required set back. Neighboring fence is approximately 2 ft from support posts.