11/07/2022 | COT - ENFC - Code Enforcement - Initial | Completed | BUILDING: EMERGENCY CALL OUT BY TFD: THERE IS MAJOR FIRE DAMAGE TO A 16 X 50 FOOT MOBILE HOME. THERE IS SEVERE DAMAGE TO THE ROOF, DECKING, WALL SHEATHING AND STUD MEMBERS IN THE LIVING ROOM AND HALLWAY. THESE STRUCTURAL MEMBERS HAVE DEEP CRACKS AND ARE CHARRED. AN ESTIMATED 14X8 AREA IN THE HALLWAY HAS SUPPORT MEMBERS AND SHEATHING THAT IS DESTROYED. MULTIPLE WINDOWS WERE DESTROYED THROUGHOUT THE UNIT.THE UNITS FLOORING HAS WATER DAMAGE. UNSAFE TO ENTER. ELECTRICAL: THE UNITS ELECTRICAL SYSTEM HAS BEEN BURNT AND WIRING THROUGHOUT THE UNIT IS BARE. ALL ELECTRICAL DEVICES ARE DAMAGED AND WET. THE ELECTRICAL SYSTEM IS NO LONGER SERVICEABLE. POWER WAS DISCONNECTED FROM THE PEDESTAL. THE PEDESTAL WAS PINNED SHUT PLUMBING GAS METER TURNED OFF. MECHANICAL: MAJOR SMOKE REMARKS: PERMITS REQUIRED. |