Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Completed

Inspection History: COT - ENFC - Code Enforcement - Initial

Case Number - CE-VIO1122-00248

Inspection Description - COT - ENFC - Code Enforcement - Initial

Inspection Status - Completed

Date Description Inspector Results Comments
11/07/2022 COT - ENFC - Code Enforcement - Initial Completed BUILDING: EMERGENCY CALL OUT BY TFD: THERE IS MAJOR FIRE DAMAGE TO A 16 X 50 FOOT MOBILE HOME. THERE IS SEVERE DAMAGE TO THE ROOF, DECKING, WALL SHEATHING AND STUD MEMBERS IN THE LIVING ROOM AND HALLWAY. THESE STRUCTURAL MEMBERS HAVE DEEP CRACKS AND ARE CHARRED. AN ESTIMATED 14X8 AREA IN THE HALLWAY HAS SUPPORT MEMBERS AND SHEATHING THAT IS DESTROYED. MULTIPLE WINDOWS WERE DESTROYED THROUGHOUT THE UNIT.THE UNITS FLOORING HAS WATER DAMAGE. UNSAFE TO ENTER.

ELECTRICAL: THE UNITS ELECTRICAL SYSTEM HAS BEEN BURNT AND WIRING THROUGHOUT THE UNIT IS BARE. ALL ELECTRICAL DEVICES ARE DAMAGED AND WET. THE ELECTRICAL SYSTEM IS NO LONGER SERVICEABLE. POWER WAS DISCONNECTED FROM THE PEDESTAL. THE PEDESTAL WAS PINNED SHUT

PLUMBING GAS METER TURNED OFF.

MECHANICAL: MAJOR SMOKE

REMARKS: PERMITS REQUIRED.