Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 107082860


Addresses:

734 W BUDMOORE TE


Inspection Status: In Violation

Inspection History: COT - ENFC - Code Enforcement - Initial

Case Number - CE-VIO0123-01277

Inspection Description - COT - ENFC - Code Enforcement - Initial

Inspection Status - In Violation

Date Description Inspector Results Comments
01/06/2023 COT - ENFC - Code Enforcement - Initial In Violation Mini Splits install without permits in a non-code compliance manner without proper ampacity or a labeled circuit breaker.

Water heater was installed in a non-code compliance manner without permits or approvals from the city of Tucson.

Rear porch has been installed without permits in a non-code compliant manner its location violates proper clearances for the energized service drop.

Multiple nonmetallic sheeting conductors have been installed at the exterior of the residence without protective conduit, watertight seals, bushings, and legible ampacity label on over current protection device. Extension cord inside the kitchen energizing a stove hood system against the UL listing and the noncompliance manner.

Roof eve has been covered with T1-11, the residence stucco meets the t1-11 not allowing proper roof ventilation. Inside the single family residence there is water intrusion, ceiling paint is bubbling as if moisture is penetrating from the rooftop. Kitchen ceiling also has paint blistering as if moisture is penetrating from the rooftop.