Status:

Closed - Resolved

Type:

Leaking A/C, back balcony railing is loose, power line down on property. Stove, refrigerator not working, some other maintenance issues. W5

Entered Date:

08/02/2022

Applicant:

N/A

Description:

Case Violations

Case Number: T22DV04350
Case Status: Closed - Resolved
Case Description: Leaking A/C, back balcony railing is loose, power line down on property. Stove, refrigerator not working, some other maintenance issues. W5
Total Violations: 6
Violation Date Code Statue
08/23/2022 T.C. Ch. 16, Sec. 16-11(e)(3) PLUMBING SYSTEMS All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
08/23/2022 T.C. Ch. 16, Sec. 16-11(e)(5) PLUMBING SYSTEMS When a structure is equipped with a gas supply system, it must be installed and maintained in a safe, hazard-free condition.
08/23/2022 T.C. Ch. 16, Sec. 16-11(a)(3) FIRE SAFETY Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
08/23/2022 T.C. Ch. 16, Sec. 16-11(b)(2) COOLING Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturers recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced.
08/23/2022 T.C. Ch. 16, Sec. 16-11(f)(4) INTERIOR SURFACES AND FEATURES Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.
08/23/2022 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition.

Completed Inspections

Case Status: Closed - Resolved
Case Number: T22DV04350
Case Description: Leaking A/C, back balcony railing is loose, power line down on property. Stove, refrigerator not working, some other maintenance issues. W5
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/19/2022 COT - ENFC - Code Enforcement - Initial Passed {Activity date: 08/19/2022; Status: Approved; Inspector: VIDAL; Comment: Entered by VIDAL - Did inspection on the unit with the tenant. Found the refrigerator not working, the gas stove has no flex line and not connected to the gas line, missing a bedroom door, toilet handle not working due to broken at the handle, handles for the tub and shower are missing, lacking smoke detectors in the bedrooms, railing on the northside missing a anchor to masonary wall, condensation line no connected in the storage room on the exterior and leaking to the floor and on the upper unit, the walkway decking have rotted ends and not supported properly and will need to be placed in several areas. Will do N.O.V. and call the management. RV.}
10/24/2023 COT - ENFC - Code Enforcement - Follow Up Passed This unit was inspected and was approved to let the unit to be rented out. Was only lacking being cleaned and was in the process of cleaning the unit. At this time the case will be closed. Violation Abated, Close Case. RV.

Completed Case Activity

Case Number - T22DV04350
Case Status: Closed - Resolved
Case Description: Leaking A/C, back balcony railing is loose, power line down on property. Stove, refrigerator not working, some other maintenance issues. W5
Description Date Status
CONTACTED BY PHONE 08/23/2022 Passed
CONTACTED BY MAILING 08/23/2022 Passed
NOTICE OF VIOLATION ISSUED 08/23/2022 Passed