Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T22DV03972
Case Details
Entered Date:
07/14/2022
Applicant:
N/A
Description:
Completed Inspections
Case Status: Closed - Resolved
Case Number: T22DV03972
Case Description: EMERGENCY CALL OUT FROM TFD
Total Completed Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/14/2022 | COT - ENFC - Code Enforcement - Initial | Completed | {Activity date: 07/14/2022; Status: Approved; Inspector: TIDWELL; Comment: Entered by TIDWELL - EMERGENCY CALL OUT BY TFD: THERE IS FIRE DAMAGE TO THE DWELLING DIMENSIONED AT 1000 SQ FEET, THE DWELLING HAS AN ENCLOSED ATTACHED FRONT ADDITION DIMENSIONED AT 16 X 22. THE ADDITION AND THE DWELLING HAVE SEVERE DAMAGE TO THE ROOF ASSEMBLY WITH ROOF PLANKING / DECKING AND THE DWELLINGS LOAD BEARING WALL MEMBERS WITH DEEP CRACKS AND MOST OF THEM HAVE BEEN DESTROYED BY THIS FIRE AND PAST FIRES. THE INTERIOR WALLS ALSO DESTROYED. ALL OF THE WINDOWS AND DOORS TO THE DWELLING / ADDITION HAVE BEEN DESTROYED. THERE ARE AREAS WHERE THE ROOF IS UNSUPPORTED AND BOWING INWARD. THE MAJORITY OF THE FLOOR DECKING AND JOISTS HAVE BEEN DESTROYED. THIS DWELLING IS A TOTAL LOSS. THE DWELLING IS UNSAFE TO ENTER. ELECTRICAL: THE DWELLINGS ELECTRICAL SYSTEM HAS BEEN BURNT THROUGHOUT. ALL ELECTRICAL DEVICES, WIRING ARE BURNT, DAMAGED AND WET. THE ELECTRICAL SYSTEM IS NO LONGER SERVICEABLE. POWER WAS DISCONNECTED FROM PREVIOUS PAST FIRES BY TEP, A CALL WAS PLACED TO TEP TO HAVE THE SERVICE DROP DISCONNECTED. PLUMBING: GAS METER WAS REMOVED FROM A PREVIOUS INCIDENT. MECHANICAL: N/A REMARKS: THE DWELLING IS A TOTAL LOSS. PERMITS ARE REQUIRED FOR DEMOLISHING. THE GATES WERE SECURED BY CITY OF TUCSON. FENCING WAS PLACED AROUND THE EXTERIOR OF THE DWELLING DUE TO THE DAMAGE AND PAST TRANSIENT ACTIVITY IDENTIFIED BY THE CITY OF TUCSON. THIS IS A VACANT AND NEGLECTED PROPERTY WITH HISTORY OF FIRES SINCE 2015. 3 PAST FIRE INCIDENTS. INSPECTOR: BETH TIDWELL DATE 07/14/2022 } |
Completed Case Activity
Case Number - T22DV03972
Case Status: Closed - Resolved
Case Description: EMERGENCY CALL OUT FROM TFD
Description | Date | Status |
CALLBACK | 07/14/2022 | Passed |
STRUCTURE SECURED BY ??? | 07/14/2022 | Passed |
CONTACTED IN PERSON | 07/14/2022 | Passed |
NOTICE AND ORDER ISSUED | 07/16/2022 | Passed |
CONTACTED BY PHONE | 07/20/2022 | Passed |
CONTACTED BY MAILING | 07/21/2022 | Passed |
NOTICE OF VIOLATION ISSUED | 07/21/2022 | Passed |
RETURNED MAIL | 08/23/2022 | Passed |