Case: T22DV03937
Case Details
Entered Date:
07/13/2022
Applicant:
2229-31 SOUTH CAMPBELL INVESTMENT PROPERTY LLC
Description:
VEHICLE INTO BUILDING
Completed Inspections
Case Status: COMPLIAN
Case Number: T22DV03937
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/13/2022 | INSP - FOLLOW UP CODE ENFORCE | valdez | Approved | ALL DOCS IN ONBASE CLOSE CASE |
| 07/13/2022 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | : EMERGENCY CALL OUT BY TPD: A VEHICLE HIT THE PERIMETER CHAIN LINK FENCE AND DROVE INTO THE FRONT ENTRY OF THE DUPLEX. THE AREA IMPACTED IS A BEARING WALL THE ESTIMATED AREA OF DAMAGE IS 8 X 6 FOOT OF AREA.THE ADJACENT PARTITION WALL ESTIMATED AT 7 X 8 FOOT OF AREA WAS PUSHED IN. THE WOOD HEADER TO THE DOOR FRAME AND THE WALL FRAMED MEMBERS ARE DAMAGED AND NO LONGER SUPPORTING THESE WALLS. THE EXTERIOR PLASTER WAS DESTROYED AT THE ABOVE LOCATIONS. THE FRONT ROOF OVERHANG'S 4X4 POST WAS KNOCKED OFF AND THE CARPORT 4 X 4 POST WAS DAMAGED. THERE IS DAMAGE TO THE SHEET ROCK ESTIMATED AT 3 X 8 FOOT AREA AT THE FRONT ENTRY AREA OF THE DWELLING. THE INTERIOR 2 X 6 CLOSET WAS DESTROYED. THERE IS SHEET ROCK DAMAGE TO THE 7 X 8 FOOT AREA OF INTERIOR PARTITION WALL ADJACENT TO THE IMPACT. ELECTRICAL: MULTIPLE CONDUCTORS AND JUNCTION BOXES WERE RIPPED FROM THE WALLS. THE EXTERIOR LIGHT FIXTURE WAS DAMAGED. POWER WAS DISCONNECTED BY TEP. PLUMBING: N/A MECHANICAL: N/A REMARKS: PERMITS REQUIRED. THE DUPLEX WAS CONDEMNED. UNSAFE TO OCCUPY. INSPECTOR: JUAN VALDEZ 7/13/2022 |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T22DV03937
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 07/13/2022 | CONTACTED IN PERSON |
| 07/13/2022 | NOTICE AND ORDER ISSUED |
| 07/13/2022 | VIOLATION CLOSED |
| 07/13/2022 | STRUCTURE SECURED BY ??? |
| 07/13/2022 | CALLBACK |