Case Details

Status:

Closed - Resolved

Type:

Rental home has numerous broken windows, debris around property, elecrical is faulty and unsafe

Entered Date:

06/21/2022

Applicant:

N/A

Description:

Case Violations

Case Number: T22DV03550
Case Status: Closed - Resolved
Case Description: Rental home has numerous broken windows, debris around property, elecrical is faulty and unsafe
Total Violations: 6
Violation Date Code Statue
09/21/2022 T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition.
09/21/2022 T.C. Ch. 16, Sec. 16-11(f)(4) INTERIOR SURFACES AND FEATURES Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.
09/21/2022 T.C. Ch. 16, Sec. 16-11(f)(3) INTERIOR SURFACES AND FEATURES Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition.
09/21/2022 T.C. Ch. 16, Sec. 16-11(c)(1) ELECTRICAL SYSTEM All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced.
09/21/2022 T.C. Ch. 16, Sec. 16-12(a)(1) EXTERIOR SURFACES, WEATHER PROTECTION All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
09/21/2022 T.C. Ch. 16, Sec. 16-11(f)(2) INTERIOR SURFACES AND FEATURES Every ceiling, roof, and ceiling and roof support must be sufficient to carry imposed loads safely, and must not buckle, sag or split due to defective material or deterioration.

Completed Inspections

Case Status: Closed - Resolved
Case Number: T22DV03550
Case Description: Rental home has numerous broken windows, debris around property, elecrical is faulty and unsafe
Total Completed Inspections - 1
End Date Description Inspector Results Comments
09/20/2022 COT - ENFC - Code Enforcement - Initial Passed {Activity date: 09/20/2022; Status: Approved; Inspector: GONZALEZ; Comment: Entered by GONZALEZ - THERE IS AN ACCUMULATION OF ANIMAL FECES, TRASH AND DEBRIS ON THE PROPERTY. THE MOBILE HOME HAS THREE BROKEN WINDOW PANES; THE KITCHEN CABINETS ARE BEING SUPPORTED BY AN AUTOMOTIVE JACK STAND. BEDROOM CEILING ISN'T ADEQUATE TO SUPPORT THE CEILING FAN'S LOAD SAFELY WHICH IS CAUSING IT TO SAG AND BUCKLE. THE CEILING IN THE KITCHEN ARE ALSO HAS SIGNS OF THE CEILING SAGGING AND BUCKLING. BATHROOM WALL RECEPTACLES ARE LOOSE NOT PROPERLY MAINTAINED IN A GOOD STATE OF REPAIR. THERE IS AN APPROXIMATELY 1X2 FT. OPEN PENETRATION IN THE BEDROOM FLOOR DECKING.} ; {Activity date: 09/20/2022; Status: Approved; Inspector: GONZALEZ; Comment: Entered by GONZALEZ - ATTEMPTED TO ESTABLISH COMMUNICATION WITH INVOLVED PARTIES.}

Completed Case Activity

Case Number - T22DV03550
Case Status: Closed - Resolved
Case Description: Rental home has numerous broken windows, debris around property, elecrical is faulty and unsafe
Description Date Status
CONTACTED BY PHONE 09/20/2022 Passed
CONTACTED IN PERSON 09/20/2022 Passed
NOTICE OF VIOLATION ISSUED 09/21/2022 Passed