Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE
Address:

Entered Date:

05/18/2022

Applicant:

XIANGFENG ZHANG & HONG CUI JT/RS

Description:

RESIDENTIAL FIRE

Case Violations

Case Number: T22DV03019
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Violations: 1
Violation Date Code Statue
05/18/2022 VIOLATION CLOSED

Outstanding Inspections

Case Number: T22DV03019
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T22DV03019
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 1
End Date Description Inspector Results Comments
05/18/2022 INSP - INITIAL CODE ENFORCMENT BERMUDEZ Approved ON SITE; TPD OFFICER WINEGARD 36819 CASE NUMBER 2205180072; TFD INSP. LOYA CASE NUMBER 2238541; UPON ARRIVAL KINDLING FOUND TFD CALL BACK TO EXTINGUISH; NO GAS TO UNIT OK PER SWG CO. ; ELECT PANELS TURNED OFF UPON ARRIVAL; ADDRESS: 1033 E PRINCE RD (1031, 1033 B) OWNER/ OCCUPANT: XIANGFENG "BOB" ZHANG & HONG CUI CAUSE OF DAMAGE: HOUSE FIRE LOCATION OF DAMAGE: NORTHEAST BEDROOM BUILDING: THERE IS FIRE DAMAGE TO THE NORTHEAST MASTER BEDROOM AREA, WINDOWS SUSTAINED FIRE DAMAGE AND ARE MISSING, FIRE INSPECTION HOLES IN CEILING DRYWALL, DRYWALL IS MISSING AND EXPOSING INSULATION. ABLE TO VIEW RAFTERS AND SHEETING, THEY ARE IN TACT WITH HEAVE SMOKE AND LITTLE FIRE DAMAGE. MULTIPLE INSPECTION HOLES IN HALLWAY, SECOND BEDROOM, LIVING ROOM AND KITCHEN AREA, EXPOSING INSULATION. THERE IS HEAVY SMOKE DAMAGE AND SOME FIRE HEAT DAMAGE TO ALL ROOMS TO INCLUDE INTERIOR NON BEARING AND BEARING WALL COVERINGS. ELECTRICAL: THE FIRE DAMAGE ZONE HAS MULTIPLE ELECTRICAL DEVICES IN CLOSE PROXIMITY TO THE FIRE. MELTED ELECTRICAL WIRING EXPOSED. UNAPPROVED WIRING METHODS FOUND AT THE 2 SERVICE PANELS LOCATED IN REAR OF BUILDING, EXPOSED ELECTRICAL WIRING AND IS NOT CODE COMPLIANT. POWER WAS DISCONNECTED BY TEP AND WILL REQUIRE CITY CLEARANCE TO RECONNECT. PLUMBING: NO GAS TO UNIT. INTERIOR PLUMBING NOT CODE COMPLIANT. MECHANICAL: MILD TO HEAVY SMOKE DAMAGE TO VENTALATION SYSTEM. REMARKS: THIS TRIPLEX IS NOW CONDEMNED AND PERMITS ARE REQUIRED FOR REPAIRS AND UTILITY RECONNECTS. OWNER WILL SECURE TRIPLEX STRUCTURE AND WILL PLACE TENANTS. INSPECTED UNITS 1031 AND 1033B NO FIRE OR WATER DAMAGE WAS SUSTAINED. EMERGENCY ORDER TO VACATE ISSUED, SIGNED AND POSTED, INDEMNIFICATION FORM SIGNED BY OWNER. DO NOT ENTER PLACARD POSTED AT FRONT OF UNITS. WILL HAVE NEW CASE INITAILIZED TO ADDRESS ILLEGAL TRIPLEX STRUCTURE, ELECT AND PLUMBING ISSUES.

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T22DV03019
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
05/18/2022 CONTACTED BY PHONE
05/18/2022 CONTACTED IN PERSON
05/18/2022 RED CROSS / PRIMAVERA
05/18/2022 NOTICE AND ORDER ISSUED
05/18/2022 POSTING/PUBLICATION
05/18/2022 STRUCTURE SECURED BY ???
05/18/2022 8-5 CITY COMM EMERGENCY

Documents

File Name Document Type  
DAMAGE REPORT 1033 E PRINCE RD.DOC DOCUMENTS VIEW
CAMSCANNER 05-18-2022 15.34.PDF DOCUMENTS VIEW
CAMSCANNER 05-18-2022 12.54.PDF DOCUMENTS VIEW
CAMSCANNER 05-18-2022 12.44.PDF DOCUMENTS VIEW