Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

05/16/2022

Applicant:

3668 S BELMAR LLC ATTN:SCOTT BRITTENHAM

Description:

Stove caused outlets to trip, was unable to fix through electrical box, Wires are sticking out from outlet with no covers. No outlets available to use in kitchen.

Case Violations

Case Number: T22DV02977
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
Violation Date Code Statue
05/26/2022 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
05/26/2022 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
07/07/2022 VIOLATION CLOSED

Completed Inspections

Case Status: COMPLIAN
Case Number: T22DV02977
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/16/2022 INSP - INITIAL CODE ENFORCMENT TIDWELL Approved ON SITE AT PROPERTY WITH TENANT THERE IS A OUTLET BOX WITH WIRING THAT IS NOT CAPPED OFF. THERE IS A GFCI IN THE KITCHEN THAT IS NOT OPERABLE AND THERE IS A GFCI ON THE OTHER WALL IN THE KITCHEN THAT APPEARS TO BE INSTALLED INCORRECTLY. THE OVEN DOES NOT WORK BECAUSE IT CAUSES THE OUTLETS TO POP AND THERE IS NO SERVICE. THE EYES ON THE STOVE CAN BE USED AND ARE GAS OPERATED. TENANT SAID THAT HE SPOKE TO LOU THE COMPLEX MAINTENCE MAN WHO IS GOING TO LOOK AT IT. I TOLD HIM THAT I WOULD CONTACT THE OWNER. IT LOOKS LIKE THERE NEEDS TO BE PROFESSIONAL SERVICE AND POSSIBLY UPDATES THAT WOULD NEED A PERMIT. THE UNIT IS OLD AND THE WIRING MAYBE COMPROMISED.
07/07/2022 INSP - FOLLOW UP CODE ENFORCE TIDWELL Approved TENANT PHONED AND SAID THAT THE ISSUES HAD BEEN TAKEN CARE OF.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T22DV02977
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
07/07/2022 CONTACTED BY PHONE
05/26/2022 CONTACTED BY MAILING
06/13/2022 CERTIFIED RECEIPT CARD
05/26/2022 NOTICE OF VIOLATION ISSUED