Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

04/26/2022

Applicant:

SAINT CYRIL OF ALEXANDRIA ROMAN CATHOLIC PARISH - TUCSON ATTN:FATHER PAUL HENSON

Description:

TFD: CALLING IN A FIRE AT A BUILDING

Case Violations

Case Number: T22DV02633
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 1
Violation Date Code Statue
04/26/2022 UDC, Sec. 6.6.2(C), (D). ACCESSORY BUILDINGS AND STRUCTURES In all zones, the buildings used for accessory uses shall comply with the following: C. An accessory structure that exceeds the allowable height of a wall within a perimeter yard and is detached from a principal structure shall comply with the perimeter yard width standards of the principal structure, except that the accessory structure may be built to a parcel line with the consent of the adjoining or, when separated by an alley, adjacent property owner(s); D. Accessory structures, such as light poles, flagpoles, and other tall and narrow structures that are similar, shall be exempt from the setback requirement. Amateur radio towers are exempt from the setback requirement and are allowed to a maximum height of 100 feet.

Outstanding Inspections

Case Number: T22DV02633
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T22DV02633
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/26/2022 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE, A CHURCH, MET WITH INSPECTOR SLAIWA, MET WITH TFD INVESTIGATORS FIRE HAD ALREADY BEEN PUT OUT, TEP WAS ONSITE AND SHUT POWER OFF TO THE BUILDING, SEVERAL PANELS RUNNING OFF A GUTTER PANEL HAD BEEN LOCKED OUT AND TEP EXITED THE SCENE. FIRE WAS LIMITED TO A PANTRY IN THE MAIN KITCHEN. DROPPED CEILING IN THE PANTRY WAS COMPLETELY BURNED, LIGHTING FIRE DAMAGED, LEAVING CEILING AND TOP OF THE WALLS EXPOSED. FOUND NO FIRE DAMAGE TO THE FRAMED WALLS OR ROOF SYSTEM. CONTENTS OF THE PANTRY INCLUDING THE SHELVING ON ALL WALLS WAS COMPLTELY BURNED, SOME DRYWALL FIRE DAMAGED AND HOLES IN THE KITHCEN WHERE TFD WAS CHASING THE FIRE. KITCHEN FLOOR RECEIVED WATER DAMAGE AND MINOR SMOKE DAMAGE TO THE KITCHEN AND HALLS. TEP WAS CALLED BACK OUT TO REMOVE LOCKS ON ALL PANELS SO THAT POWER COULD BE ISOLATED , PANTRY AND KITCHEN PANELS WERE LEFT OFF AND POWER RESTORED TO THE BUILDING AND SURROUNDING BUILDINGS. NOV WAS ISSUED ON SITE AND SIGNED FOR BY THE RESIDENT PREIST. MAINTANENCE HAD ALREADY CALLED THEIR ELECTRICIAN AND INSURANCE WAS IN ROUTE TO THE PROPERTY. NO SECURING WAS REQUIRED. ELECTRICAL AND MECHANICAL EQUIPMENT WERE BOTH SECURED INSIDE A WROUGHT IRON FENCED AREA.
04/26/2022 INSP - INITIAL CODE ENFORCMENT SLAIWA Approved ON SITE, WITH GG TRAINING.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T22DV02633
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
04/27/2022 CONTACTED BY MAILING