Case Details

Status:

Closed - Resolved

Type:

CONVERTED SHED INTO LIVING QUARTERS, UNAPPROVED ELECTRICAL WIRING
Address:

Entered Date:

04/21/2022

Applicant:

N/A

Description:

Completed Inspections

Case Status: Closed - Resolved
Case Number: T22DV02587
Case Description: CONVERTED SHED INTO LIVING QUARTERS, UNAPPROVED ELECTRICAL WIRING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/21/2022 COT - ENFC - Code Enforcement - Initial Passed {Activity date: 04/21/2022; Status: Approved; Inspector: GONZALEZ; Comment: Entered by GONZALEZ - *PREVIOUSLY APPROVED ELECTRICAL ATTACHED TO THE FENCE HAS BEEN TERMINATED. CONDUIT HAS ONLY ONE CONDUCTOR INSIDE OF IT AND NOT ENERGIZED. THESE CONDUCTORS WERE USED TO ENERGIZE THREE APPROVED PANELS THAT HAVE BEEN MODIFIED FROM ITS ORIGINAL INSTALLATION. REAR SHED HAS BEEN CONVERTED INTO A LIVING QUARTER WITHOUT PERMITS OR APPROVALS FROM THE CITY OF TUCSON. THERE IS ELECTRICAL AND PLUMBING CONNECTED TO THE SHED. A BATHROOM WINDOW WITHOUT A PROPER LINTEL HAS BEEN INSTALLED IN THE NORTHWEST CORNER OF THE MASONRY BUILDING. THERE ARE CRACKS AND SIGNS OF SHIFTING NEAR THE NEWLY INSTALLED WINDOW AND THE CORNER OF THE BUILDING. THERE IS A MINI SPLIT INSTALLED TO COOL THE SHED AND A PROPANE STOVE BEING USED FOR COOKING WITHOUT PROPER MECHANICAL VENTILATION. A BATHROOM AREA HAS BEEN MADE INSIDE THE SHED WITH SEWER AND WATER CONNECTIONS. BREAKER ENERGIZING THE CONDUCTORS ARE INSIDE UNIT 1'S ELECTRICAL MAIN SERVICE. IT HAS BEEN DISCONNECTED BY OWNER TO PREVENT POWER TO BE REINSTATED. UNIT 1 HAS NONMETALLIC SHEATHING ENERGIZING AN EVAPORATIVE COOLER BY ENTERING ITS DUCTWORK IN A DAMP ENVIRONMENT. THERE ARE UNAPPROVED WIRES PLUGGED INTO OTHER ELECTRICAL RECEPTACLES TO ENERGIZE NEWLY INSTALLED RECEPTACLES WITHOUT PROPER ELECTRICAL BOXES IN A NON-CODE COMPLAINT MANNER. GFCI NEED TO BE VERIFIED IN THE KITCHEN FOR PROPER WIRING DUE TO THE MOBILE HOME ORIGINALLY BEING A TWO WIRE SYSTEM UNIT 2 HAS AN ENERGIZED INTERIOR DOWNSTREAM PANEL ATTACHED TO THE EXTERIOR OF THE MOBILE HOME WITHOUT ANY MOISTURE PROTECTION. OWNER HAS BEEN NOTIFIED TO KEEP POWER OFF, SHED VACANT AND SECURED. PERMITS ARE REQUIRED TO MAKE ALL CORRECTIONS TO BOTH MOBILE HOMES. SHED HAS BEEN POSTED TO KEEP VACANT, DOCUMENTS HAVE BEEN SIGNED AND ACKNOWLEDGED. }
08/31/2022 COT - ENFC - Code Enforcement - Follow Up Passed {Activity date: 08/31/2022; Status: Approved; Inspector: GONZALEZ; Comment: Entered by GONZALEZ - PLANS TO GAIN PERMITS AND APPROVALS HAVE BEEN SUBMITTED UNDER ACTIVITY NUMBERS: T22CM05536, T22CM05537, T21CM01601.} ; {Activity date: 07/19/2022; Status: Approved; Inspector: GONZALEZ; Comment: Entered by GONZALEZ - CREW ON SITE, CLEANING THE PROPERTY.}

Completed Case Activity

Case Number - T22DV02587
Case Status: Closed - Resolved
Case Description: CONVERTED SHED INTO LIVING QUARTERS, UNAPPROVED ELECTRICAL WIRING
Description Date Status
CONTACTED IN PERSON 04/21/2022 Passed
NOTICE OF VIOLATION ISSUED 04/21/2022 Passed
CONTACTED BY PHONE 07/21/2022 Passed

Documents

File Name Document Type  
IMG_4540.JPG IMAGES VIEW
IMG_4539.JPG IMAGES VIEW
IMG_4538.JPG IMAGES VIEW
IMG_4537.JPG IMAGES VIEW
IMG_4534.JPG IMAGES VIEW
IMG_4544.JPG IMAGES VIEW
IMG_4543.JPG IMAGES VIEW