Completed Inspections
Case Status: Closed - Resolved
Case Number: T22DV02551
Case Description: Putting up a patio
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/27/2023 | COT - ENFC - Code Enforcement - Initial | Passed | VISITED SITE, SMALL RAMADA IN THE REAR YARD WAS 10 FT X 10FT AND WELL WITHIN THE SETBACKS. RAMADA WAS OVERBUILT, USING 2X8 RAFTERS 24"OC. BEAMS AND POSTS WERE 4X8. ROOF WAS LITE WEIGHT CORIGATED METAL. ALL TIE DOWN METAL STRAPS AND HANGERS WERE PROPER SIZED AND DECORATIVE BEAM SADDLES WERE HEAVY DECORATIVE 1/4 " METAL AND ALL CONNECTIONS SADDLES AND POST BASE USED 1/2" LAGS. RAMADA WAS UNDER SIZED AND OVERBUILT. THERE ARE NO VIOLATIONS AND ERMITS ARE NOT REQUIRED FOR STRUCTURE UNDER 200 SF. CLOSE CASE. |