Case: T22DV01846
Case Details
Entered Date:
03/16/2022
Applicant:
DESERT CHRISTIAN SCHOOLS INC
Description:
BUILDING FIRE
Outstanding Inspections
Case Number: T22DV01846
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T22DV01846
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/16/2022 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | EMERGENCY CALL OUT BY TUCSON FIRE DEPARTMENT: THERE IS SEVERE FIRE DAMAGE TO THE MODULAR BUILDING THE ROOF ASSEMBLY, FLOOR JOISTS, ROOF AND FLOOR DECKING, AND BEARING WALLS OF THE BUILDING. THE BUILDING IS DIMENSIONED AT 24 FEET X 60 FEET. THE REAR 24 X 30 FOOT SECTION OF THE BUILDING HAS THE ROOF, CEILING AND JOIST MEMBERS WHICH HAVE BEEN DESTROYED BY FIRE. THE REMAINING WALL STUDS AND FLOOR JOIST HAVE DEEP CRACKS WITH EXTERIOR AREAS WHICH ARE CHARRED. THE BUILDING HAS MULTIPLE EXTERIOR WALL PANELS DAMAGED BY FIRE AND CUT BY TUCSON FIRE DEPARTMENT. THE ENTIRE INTERIOR OF THE BUILDING'S WALLS AND CEILING HAVE SEVERE FIRE AND WATER DAMAGE. THE BUILDING IS NOT SAFE TO ENTER. ELECTRICAL: THERE IS BURNT AND BARE WIRING THROUGHOUT THE BUILDING. CEILING LIGHT FIXTURES AND DEVICES ARE DAMAGED BY FIRE OR WATER. TUCSON POWER AND ELECTRIC DID REMOVE THE METER AND HAD POWER DISCONNECTED AT THE TRANSFORMER. PLUMBING: N/A MECHANICAL: HEAVY SMOKE, WALL MOUNTED HVAC IS DAMAGED. REMARKS: THE BUILDING IS A TOTAL LOSS. A NOTICE AND ORDER WAS POSTED UNSAFE TO ENTER. A NOTICE OF VIOLATION WILL FOLLOW FOR DEMOLISHMENT OF THE BUILDING. THE PERIMETER AREA OF THE BUILDING WAS FENCED. |
| 08/31/2022 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | THE FIRE DAMAGED UNIT WAS REMOVED, CLOSE CASE |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T22DV01846
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 8
| Date | Name |
| 03/22/2022 | CONTACTED BY PHONE |
| 03/16/2022 | CONTACTED IN PERSON |
| 03/25/2022 | CONTACTED BY MAILING |
| 03/24/2022 | NOTICE AND ORDER ISSUED |
| 03/24/2022 | NOTICE OF VIOLATION ISSUED |
| 03/16/2022 | VIOLATION CLOSED |
| 03/16/2022 | STRUCTURE SECURED BY ??? |
| 03/16/2022 | CALLBACK |