Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

02/13/2022

Applicant:

BARBARA PANUNZIO

Description:

HOUSE FIRE EVENT F220440188

Completed Inspections

Case Status: COMPLIAN
Case Number: T22DV01160
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/13/2022 INSP - INITIAL CODE ENFORCMENT BERMUDEZ Approved ADDRESS: 740 N EVELYN AV OWNER/ OCCUPANT: BARBARA PANUNZIO CAUSE OF DAMAGE: HOUSE FIRE LOCATION OF DAMAGE: NORTHWEST BEDROOM BUILDING: THERE IS FIRE DAMAGE TO THE NORTHWEST MASTER BEDROOM AREA, WINDOWS SUSTAINED FIRE DAMAGE AND ARE MISSING, FIRE INSPECTION HOLES IN CEILING DRYWALL, EXPOSING INSULATION. ABLE TO VIEW RAFTERS AND SHEETING STILL IN TACT WITH NO SMOKE OR FIRE DAMAGE. THERE IS HEAVY SMOKE DAMAGE TO MASTER BEDROOM AND BATHROOM INTERIOR NON BEARING AND BEARING WALL COVERINGS. HEAVY SMOKE DAMAGE IN HALLWAY LEADING INTO OTHER BEDROOMS AND FOYER. ELECTRICAL: THE FIRE DAMAGE ZONE HAS MULTIPLE ELECTRICAL DEVICES IN CLOSE PROXIMITY TO THE FIRE. MELTED ELECTRICAL WIRING EXPOSED. UNAPPROVED WIRING METHODS FOUND AT THE SERVICE PANEL, MISSING EXTERIOR ELECTRICAL CONDUIT, EXPOSING ELECTRICAL WIRING AND IS NOT CODE COMPLIANT. POWER WAS DISCONNECTED BY TEP, METER WAS PULLED. PLUMBING: SOUTHWEST GAS DISCONNECTED AND LOCKED GAS SERVICE. MECHANICAL: MILD TO HEAVY SMOKE DAMAGE TO VENTALATION SYSTEM. REMARKS: THIS HOME IS NOW CONDEMNED AND PERMITS ARE REQUIRED FOR REPAIRS AND UTILITY RECONNECTS. OWNER WILL SECURE THE HOME. WILL CLOSE CASE AT THIS TIME.
03/17/2022 INSP - FOLLOW UP CODE ENFORCE MENDOZA Approved NOTES MODIFIED 4/5/22 MET WITH CONTRACTOR 3/17/22. DISCUSSED ALL ELECTRICAL, BUILDING ISSUES. CONTRACTOR WILL OBTAIN ELECTRICAL PERMIT FOR ELECRICAL REPAIRS TO DAMAGED CIRCUIT IN THE BEDROOM, REPAIR OF ANY OUT OF CODE EXTERIOR RUNS AND POSSIBLE ELECTRICAL UPGRADE/SUBPANEL ADDITION IF INSTALLED NO STRUCTUAL FIRE DAMAGE TO THE INTERIOR OF THE UNIT. NO BURNING ON THE ROOF JOISTS OR WALL STUDS. HEAVY SMOKE DAMAGE TO THE BEDROOM DRYWALL ONLY. AS WELL AS A SMALL PORTION OF THE HALLWAY. ONE ELECTRICAL FAN CIRCUIT ON THE CEILING IS DAMAGED. NO WATER DAMAGE IN THE UNIT. OKAY TO BEGIN SOFT DEMO OF ALL DAMAGED DRYWALL, DAMAGED ELECTRICAL RUN, CARPET AND PROPERTY IN THE BEDROOM AND HALLWAY. ALSO OKAY TO BEGIN CLEANING OF STRUCTURE SMOKE DAMAGE.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T22DV01160
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
03/24/2022 CONTACTED BY PHONE
02/14/2022 CONTACTED IN PERSON
02/14/2022 NOTICE AND ORDER ISSUED
02/14/2022 VIOLATION CLOSED
02/14/2022 STRUCTURE SECURED BY ???
02/14/2022 CALLBACK

Documents

File Name Document Type  
DAMAGE REPORT 740 N EVELYN AV RFIRE.DOC DOCUMENTS VIEW
CAMSCANNER 02-14-2022 10.09.PDF DOCUMENTS VIEW