Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

10/31/2021

Applicant:

BRITTON TRAVIS & AMANDA CP/RS

Description:

ELECTRICAL FIRE

Outstanding Inspections

Case Number: T21DV07693
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T21DV07693
Case Description: EMERGENCY
Total Completed Inspections - 1
End Date Description Inspector Results Comments
10/31/2021 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TFD: THERE ARE 2 INSPECTION HOLES IN THE GARAGE SHEETROCK. THE HOLES DO NOT PENETRATE INTO THE INTERIOR. THE SHEET ROCK HAS NAIL HEADS SHOWING. THE SHEETROCK HAS A SMOKE FILM. ELECTRICAL: THE GFCI WALL OUTLET COVER PLATE IS MELTED. THE CIRCUIT BREAKER NUMBER 17 DID TRIP. A BATTERY OPERATED APPLIANCE WAS PLUGGED INTO THE OUTLET. THE 2 CEILING LIGHT FIXTURES HAVE SMOKE POSSIBLE HEAT DAMAGE, CIRCUIT BREAKER NUMBER 8 WAS SHUT OFF. THE GARAGE IS WITHOUT POWER AND BATHROOM NUMBER 2. CIRCUIT BREAKER NUMBER 17 IS WALL OUTLETS GARAGE. CIRCUIT BREAKER NUMBER 8 IS GARAGE AND BATHROOM 2 LIGHTING. PLUMBING: OK TO LEAVE ON, BY SWG MECHANICAL: MILD SMOKE IN ALL ROOMS REMARKS: PERMIT REQUIRED FOR ELECTRICAL REPAIRS. OCCUPANCY CONTINUES AFTER SMOKE CLEARS, CIRCUIT BREAKER NUMBER 8 AND 17 SHALL REMAIN OFF. LICENSED CONTRACTOR REQUIRED OWNER WAS ADVISED A PERMIT IS REQUIRED FOR THE REPAIR. NOTICE WAS SIGNED , CLOSE CASE

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T21DV07693
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
10/31/2021 CONTACTED IN PERSON
10/31/2021 NOTICE AND ORDER ISSUED
10/31/2021 VIOLATION CLOSED

Documents

File Name Document Type  
7156 NOV.PDF DOCUMENTS VIEW
7156 S VIA GAUCHO VIEJO.PDF DOCUMENTS VIEW
20211031_190549.JPG DOCUMENTS VIEW
20211031_190529.JPG DOCUMENTS VIEW
20211031_185009.JPG DOCUMENTS VIEW